ÄKTA pure 25 L
參數(shù) | ÄKTA pure 25 L |
---|---|
Application | Flexible and intuitive chromatography system for fast purification of proteins, peptides, and nucleic acids from microgram to gram levels of target product. |
Application supported | Affinity chromatography, size exclusion chromatography (SEC, also known as gel filtration), ion exchange chromatography, hydrophobic interaction chromatography, and reversed phase chromatography (RPC). For RPC runs use only Frac F9-R or F9-T. |
Automatic buffer preparation | No |
Autosampler injection | No (optional) |
Buffer selection | Upgradeable to 14 inlets |
Compliance | The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from Cytiva. |
Depth | 470 mm |
Flow cell path length | 2 mm (optional 5 mm) |
Flow rate | 0.001 to 25 mL/min (normal range), 0.01 to 50 mL/min (column packing flow) |
Height | 629 mm |
Multiple sample injection | Upgradeable to 5 samples |
Multiple wavelength detection | Fixed wavelength |
Multistep purification | Yes, (optional) |
Operating pressure (sample pump) max. | N/A |
Operating pressure max. | 20 MPa (2900 psi) |
Power consumption | 300 VA |
Protection class | IP 21 |
Pump type | Piston pump, metering type |
Relative humidity | 20% to 95% (noncondensing) |
Safety certifications | CE, ETL, UKCA, EAC, KC, RCM |
Tubing i.d. (flow path) | 0.5 mm |
UV wavelength | 280 nm |
Viscosity | 0.35 to 10.0 cP (system pump) |
Voltage | 100 to 120/220 to 240 VAC |
Weight | Up to 53 kg |
Width | 535 mm |
pH monitoring | 0 to 14 |
pH stability, cleaning-in-place (CIP) | 0 to 14 |
pH stability, operational | 2 to 12 |
Model | ÄKTA pure 25 L |
ÄKTA pure 150 L
參數(shù) | ÄKTA pure 150 L |
---|---|
Application | Tailored and reliable chromatography system for fast purification of proteins, peptides, and nucleic acids from microgram to tens of gram levels of target product. |
Application supported | Affinity chromatography, size exclusion chromatography (SEC, also known as gel filtration), ion exchange chromatography, hydrophobic interaction chromatography, and reversed phase chromatography (RPC). For RPC runs use only Frac F9-R. |
Automatic buffer preparation | No |
Autosampler injection | No (optional) |
Buffer selection | Upgradeable to 14 inlets |
Compliance | The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from Cytiva. |
Depth | 470 mm |
Flow cell path length | 2 mm (optional 5 mm) |
Flow rate | 0.01 to 150 mL/min (normal range), 0.01 to 300 mL/min (column packing flow) |
Height | 629 mm |
Multiple sample injection | Upgradeable to 5 samples |
Multiple wavelength detection | Fixed wavelength |
Multistep purification | Yes, (optional) |
Operating pressure (sample pump) max. | 5 MPa (725 psi) |
Operating pressure max. | 5 Mpa (725 psi) |
Power consumption | 300 VA |
Protection class | IP 21 |
Pump type | Piston pump, metering type |
Relative humidity | 20% to 95% (noncondensing) |
Safety certifications | CE, ETL, UKCA, EAC, KC, RCM |
Tubing i.d. (flow path) | 0.75 mm |
UV wavelength | 280 nm |
Viscosity | 0.35 to 5.0 cP (system pump), 0.7 to 10.0 cP (sample pump) |
Voltage | 100 to 120/220 to 240 VAC |
Weight | Up to 53 kg |
Width | 535 mm |
pH monitoring | 0 to 14 (optional) |
pH stability, cleaning-in-place (CIP) | 0 to 14 |
pH stability, operational | 2 to 12 |
Model | ÄKTA pure 150 L |