圖1、圖2、圖3 分別為AWM3100/AWM3300氣體質量流量傳感器內部的發(fā)熱器控制電路、雙傳感電路、差分放大電路圖。
圖1AWM3100/AWM3300氣體質量流量傳感器內部的發(fā)熱器控制電路 圖2 AWM3100/AWM3300氣體質量流量傳感器內部的雙傳感電路
3圖 AWM3100/AWM3300氣體質量流量傳感器內部的差分放大電路圖
AWM3000系列氣體質量流量傳感器技術規(guī)格:10.0±0.01VDC
AWM3100V | AWM3150V | AWM3200V | AWM3300V | |||
流量范圍(span) | +200sccm | +30sccm | +1000sccm | |||
壓力范圍(psi) | ||||||
(參照附錄) | ± | |||||
輸出電壓 | 5VDC@ | 3.4VDC@ | 5VDC@ | 5VDC | ||
@ 標定點 | 200sccm | 25sccm | | 1000sccm | ||
零點電壓 | 1.00±0.05VDC | 1.00±0.1VDC | 1.00±0.08mV | 1.00±0.1VDC | ||
零點漂移 | ||||||
+25~-25?C | ±25mV | ±100mV | ±25mV | ±25mV | ||
+25~+85?C | ||||||
輸出電壓漂移 | ||||||
Max | ||||||
+25~-25?C | -4% 讀數(shù) | ±5.0% 讀數(shù) | +24.0% 讀數(shù) | -5% 讀數(shù) | ||
+25~+85?C | +4% 讀數(shù) | ±5.0% 讀數(shù) | -24.0% 讀數(shù) | +5% 讀數(shù) | ||
重復性& 遲滯Max | ±0.5% 讀數(shù) | ± 1% 讀數(shù) | ±0.5% 讀數(shù) | ±1% 讀數(shù) | ||
Min Typ. | Max. | |||||
電源(VDC) | 8.0 10±0.01 | 15 (2) | ||||
功耗(mW) | 50 | 60 | ||||
反應時間(ms) | 1.0 | 3.0 (1) | ||||
共模壓力(psi) &, lt;, /TD> | | 25 | ||||
工作溫度 | -25~85?C | |||||
儲存溫度(?C) | -40~90?C | |||||
沖擊(5drops,6axis) | |
注:1、信號處理zui初預熱所須時間zui多1 分鐘
2、輸出電壓隨電源電壓而比率變化
3、差壓器件的溫漂主要是由氣體的濃度隨溫度而變化
氣流器件的溫漂主要是薄膜TCR 的系數(shù)的二次根及厚膜電阻的溫飄,加上運放的溫飄
4、為防止損壞,zui大允許流量變化值:5.0SLPM/1.0 秒
AWM3000系列氣體質量流量傳感器*型號:
*型號 | 量程 |
AWM3100V | +200SCCM |
AWM3201CR | ± |
AWM3200V | ± |