Measurement of bolting machines |
● TORQUE TESTER DIS-IPS |
Performance check of an electric driver Management of the bolting torque of an automatic line A new function is carried (1) Display Board Became Legible. (A Measurement modea unit. Other coded data is displayed.) (2) Fault charge protection loading. It is pilot-lamp lighting during charge. Detection part is very a compact! The best for measurement of an automatic line OW join. it rewinds atis needlessness. Disply screen became large. It is very legible .It became large 1.5times. Various attachments are attached. Measurement is possible,with a bit attached. The main features □ Yes-no decision □ Average calculation □ Data storage is 800 affairs. □ A convenient functional setup of a setup of a measurement start value etc. □ Data output at real time (every about 1/180 seconds). □ USB terminal data output |
DIS-IPS | ||||
Specification | DIS-IPS20C | DIS-IPS5C | ||
Measuring range | 0.20~20 N・m 2.0~200 kgf・cm 2.0~180 lbf・in | 0.020~5 N・m 0.20~50 kgf・cm 0.20~45 lbf・in | ||
Accuracy | ±0.5% (499 or less digit±3digit) | |||
Display | The 4 figures digital display of LCD | |||
The measurement direction | CW-CCW (rightleft) | |||
Measuring mode | P-P Peak | Peak load value hold. | ||
T-R Track | Indication of real time torque value. | |||
P-D Peak down | Holding Load Value at the moment to change from upward to downword. | |||
C Real-time output | Load torque value is outputted every about1/ 180 second . | |||
Decision function | Setting of torque value | A maximuma minimum value are in a measuring range,a setup is possible. Can confirm the set value by the buzzer sound or LED. | ||
Automatic Clearance | Automatically clear the displayed value after certain time (0.5 - 3.0 sec,selectable at each 0.5 sec). Setting 0.0 sec for manual Zero clearance | |||
One-touch-Zero Clearance | Easy Zero-Adjustment with pressing CLEAR button | |||
The Maximum, the minimum,the average value | Displays, memoryoutput the data number, the maximum, the minimum,the average value of the measured value to 30 data. It can save by a maximum of 10 channels. | |||
Data spec. | Data transfer | ASCII format (Baud rate : 19200) | ||
Data memory | 800 data stored | |||
Power supply | Ni-Cd chargeable battery 1.2V×5cells 700mAh | |||
Auto power save | 10 minutes no use, automatically switch off. | |||
Charging time | From empty - about 3hours | |||
Continunous working time | 12 hours | |||
Attachment fit mouth | □20mm | |||
Meter outside type dimension | 100(W)×105(D)×33(H) | |||
Weight | Meter part 520g | |||
Attachment | Fixed Attachment □20㎜ M4/M5/M6/M8 | |||
OW joint OW-20 | OW joint OW-10 | |||
Accessories (one piece each) | AC/DC adaptor (Please choose AC adaptor out of 120V,230V.) | |||
An inspection report, a proofreading certificate, a traceability system figure |
OW joint is a measurement end at one-touch. It binds tightmeasurement is completed only by the work of a direction. Inversion operation like the former is unnecessary.Since the fit part with a bit is the screw head, where a bit is attached, it can be measured.By the conventional method, friction of a screw part had affected the measurement result.This joint has the structure where it is not influenced of fricative,can manage torque stabilized over the long period of time |