  • 96040A Low Phase Noise Reference Source

96040A Low Phase Noise Reference Source

參考價(jià)
面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 型號(hào)
  • 品牌
  • 所在地廣州市
  • 更新時(shí)間2022-12-19
  • 廠商性質(zhì)其他
  • 入駐年限1
  • 實(shí)名認(rèn)證已認(rèn)證
  • 產(chǎn)品數(shù)量1985
  • 人氣值3654
產(chǎn)品標(biāo)簽

客服在線 索取相關(guān)資料 在線詢價(jià)

聯(lián)系方式:經(jīng)理 查看聯(lián)系方式

聯(lián)系我們時(shí)請(qǐng)說(shuō)明是 儀表網(wǎng) 上看到的信息,謝謝!

同類產(chǎn)品
綠測(cè)科技是一家專注于提供測(cè)試與測(cè)量解決方案的技術(shù)型服務(wù)公司??偛吭O(shè)立于廣州羊城。隨著業(yè)務(wù)的發(fā)展,又先后在廣西、湖南、武漢等地設(shè)立了分公司。綠測(cè)科技主要業(yè)務(wù)范圍分為三個(gè)方向:數(shù)據(jù)采集卡、測(cè)試測(cè)量?jī)x器、智能測(cè)試系統(tǒng)。綠測(cè)科技既研發(fā)自主產(chǎn)品同時(shí)也是多家儀器設(shè)備廠商的代理商。綠測(cè)科技整合更多的資源向廣大用戶提供:高速數(shù)據(jù)采集、無(wú)線通信測(cè)試方案、材料與器件測(cè)試方案、EMC測(cè)試方案、智能車聯(lián)網(wǎng)測(cè)試方案、物聯(lián)網(wǎng)測(cè)試方案以及IC測(cè)試方案、新能源汽車測(cè)試方案等等。主營(yíng)業(yè)務(wù)版塊數(shù)據(jù)采集卡:32G/6bit 采集卡、10G/8bit 采集卡、6.4G/12bit 采集卡、3G/14bit采集卡、1G/14bit采集卡測(cè)試儀器設(shè)備:電池測(cè)試儀、微電阻計(jì)、高阻計(jì)、LCR測(cè)試儀、交/直流電子負(fù)載、功率計(jì)、功率分析儀、記錄儀、EMC電磁兼容測(cè)試設(shè)備、安規(guī)測(cè)試儀、高速攝像系統(tǒng)、紅外熱成像儀、示波器、實(shí)驗(yàn)室管理系統(tǒng)、頻譜與信號(hào)分析儀、網(wǎng)絡(luò)分析儀、電能質(zhì)量分析儀、信號(hào)發(fā)生器、光譜分析儀、光功率計(jì)、無(wú)線信號(hào)綜測(cè)儀、交/直流電源、誤碼分析儀、脈沖線圈測(cè)試儀、ASK/FSK 綜合測(cè)試儀、功率放大器、阻抗分析儀、噪聲分析儀環(huán)境測(cè)試設(shè)備:冷熱沖擊箱、恒溫恒濕箱、振動(dòng)試驗(yàn)機(jī)、三綜合測(cè)試系統(tǒng)、鹽霧試驗(yàn)箱、光照試驗(yàn)室測(cè)試系統(tǒng):無(wú)線充電測(cè)試系統(tǒng)、無(wú)線充電線圈測(cè)試系統(tǒng)、車載充電機(jī)/充電樁測(cè)試系統(tǒng)、無(wú)人機(jī)教育系統(tǒng)測(cè)試環(huán)境:EMC屏蔽房、EMC暗室、老化房、半消音/全消音試驗(yàn)室、汽車碰撞燈光系統(tǒng)
點(diǎn)擊展示更多內(nèi)容
96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source 產(chǎn)品詳情

Simplify your RF calibration system

The Fluke Calibration 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system. Its precision signal level and attenuation, high signal purity and precision low distortion modulation make this reference source superior to the general-purpose signal generators that are often used to calibrate spectrum analyzers, modulation meters, RF sensors, attenuators, and similar instruments. Its low phase noise provides superior phase noise performance.

Unlike many RF calibration solutions, the 96040A is designed specifically for RF calibration, with a calibration-oriented user interface that makes it easy to learn and use. The 96040A speeds up calibration procedures, reduces opportunities for operator errors, and greatly simplifies RF metrology. As the core of an RF and microwave calibration system, the 96040A covers the majority of test points required for calibrating spectrum analyzers of any frequency range.

Automated with MET/CAL® Plus Calibration Management Software, the 96040A reduces complexity and calibration times, dramatically improving efficiency and increasing capacity by 50 % or more over manual methods.

Key benefits


Broad, versatile workload coverage

The 96040A calibrates a broad workload of RF calibration devices, including:

• Spectrum analyzers

• Modulation meters and analyzers

• RF power meters and sensors

• Frequency counters

• Attenuators

• And more

The metrology associated with calibrating these items becomes simpler because you have fewer error sources and uncertainty contributions to consider.

More than just an RF calibrator

There are many applications in research and development, manufacturing test, and ATE needing better performance than a general purpose signal generator. If wide frequency coverage, frequency resolution, low harmonics, phase noise and spurious content, signal level and attenuation accuracy, or dynamic range are critical parameters the 96040A is an ideal solution.

Cut the cost of your RF calibration system in half

As the central instrument in a high capability RF spectrum analyzer calibration system, the 96040A can cut your costs in half. The 96040A replaces all of these parts of a “typical” RF calibration system:

Up to four signal sources (from audio/ function generators to RF signal and low phase noise sources)

  • Power meters and power sensors
  • Step attenuators
  • Filters
  • Pads
  • Couplers
  • 50 MHz frequency counter

The 96040A not only reduces the initial need to purchase, install and configure RF system components, but it also reduces the maintenance and calibration costs associated with all of that equipment. The 96040A is also easier to transport than a heavy rack of equipment and accessories, making it a good solution for on-site calibration.

With its 4 GHz frequency range, the 96040A performs more than 80 % of all the tests required on high performance, high frequency spectrum analyzers.

For workload items that require frequencies beyond 4 GHz, you can use an RF and microwave source that you probably already own alongside the 96040A to address the few remaining higher frequency test points. For many spectrum analyzer models operating below 4 GHz, you only need a 96040A to perform the entire calibration. You can’t simplify much more than that!

No need for additional function generators

The 9640A Reference Source’s internal modulation capability makes it suitable for applications that require precision modulation to be applied to the output signal, such as modulation analyzer calibration and spectrum analyzer sweep time testing using an AM signal with more accurate modulation rates. You don’t need additional function generators as a low frequency modulation source—the 96040A delivers it all.

Designed for RF calibration

The 96040A user interface is designed to simplify processes for calibrating typical items in your workload, such as spectrum analyzers, RF level meters and receivers. Parameter offset, stepping, relative and DUT error readout modes allow you to work accurately and efficiently, following familiar calibration procedures. You’ll find it easier than ever to determine the performance and tolerances of units under test.

The 96040A front panel is equipped with dedicated function keys, context-sensitive softkeys, and a bright, easy-to-read color display that make it easy to learn and operate. You can set output levels in terms of power (watts or dBm), voltage (RMS or peak to peak) using familiar multipliers and exponent forms. You can move easily between voltage, power and dBm units without losing entered values or accuracy. In error readout mode to adjust the reading, simply rotate the spin wheel and the DUT error is displayed directly in dB, ppm or percent.

The simple, calibration-oriented user interface also makes troubleshooting easier if you encounter an unexpected result or an out-of-tolerance condition while following a manual or automated calibration procedure.

“What you set is what you get” accuracy and signal purity

A rugged, precise levelling head delivers 96040A signal levels directly to the device under test (DUT) input just the way you set them on the front panel. This unique “What you set is what you get” feature helps you avoid problems like losses, noise, interference, and mismatch errors, which can be caused by using intermediate connectors and cables. This approach also maintains the integrity of low-level signals. The head maintains signal precision and noise immunity throughout a 154 dB dynamic range, down to the very lowest levels at -130 dBm.

The leveling head reduces lead changes from 25 to just 5 during a typical calibration, allowing you to “connect once and test many,” extending unattended times in an automated system, and reducing connector wear.

Calibrated as a system to assure system performance

The 96040A is supplied with a 50 ohm leveling head. The /75 model has both 50 ohm and 75 ohm leveling heads. Each mainframe and head are calibrated together as a complete system. System calibration helps assure overall system performance. Each 96040A instrument is supplied with a comprehensive ISO 17025 compliant certificate of calibration with data for all key parameters, including level and attenuation, output VSWR, and phase noise. You can be assured that your 96040A is traceable, plus RF metrology and uncertainty analysis become much simpler and faster. Accredited certification is available for the 96040A and both 50 ohm and 75 ohm heads.

State-of-the-art phase noise performance

With reduced low phase noise optimized for low and high offset frequencies and specifications from 1 Hz to 10 MHz offsets, the 96040A offers exceptional phase noise performance beyond that required for today’s high performance workloads.

Phase noise data is included in the 96040A certificate of calibration. Instead of relying only on the more conservative guaranteed specifications, users have actual performance data for their unit. Even with the best low phase noise signal generators, filters are commonly used during spectrum analyzer phase noise calibration tests, reducing noise levels at wide (high) offset frequencies to improve test margins. The 9600FLT 1 GHz bandpass filter accessory is designed specifically for high performance spectrum analyzer wide-offset phase noise testing and connects easily to 96040A models in either benchtop or rack-mounted applications.

Selectable frequency reference input/ output expands functionality

Selectable external frequency reference input is available as a standard feature on the rear panel of the 96040A. The input allows you to lock the frequency output to an external reference, such as the Fluke Calibration 910R Rubidium Standard, for applications where high clock accuracy or use of a common reference frequency is important. The frequency reference output allows a DUT to be frequency locked to the 96040A internal reference clock. This configuration is often required to reduce frequency offset errors that may occur between the reference source and the DUT.

Simplify frequency response tests with 96040A sweep functions

RF applications often require a frequency sweep. The 96040A’s sweep functions simplify the application of manual legacy spectrum analyzer frequency response testing, as well as filter response measurements.

Automate with MET/CAL® software for “walk-away” efficiency

In a typical automated RF calibration process, the operator must frequently intervene to change test setups, thus limiting the benefits that can be realized by the automation. Walk-away automation can increase calibration system capacity by up to 25 percent using procedures you develop in MET/CAL Calibration Management Software. For example, the manufacturer’s calibration procedure for calibrating the Agilent E4407B 26.5 GHz spectrum analyzer requires 27 different and complex test setups. On the other hand, the 96040A, used with MET/CAL Calibration Management Software, can perform the major core of required tests with a single setup. Only six additional setups would be needed using a MET/CAL procedure.

MET/CAL procedures created by Fluke Calibration for the 9640A models can be used by the 96040A in 9640A emulation mode. Optimized automated procedures can save time for the operators by allowing them to leave the system running while attending to other work. For example, the E4407B MET/CAL procedure for the legacy 9640A, running in emulation mode on the 96040A, allows for a total 90 minutes of “walkaway” time within the total two-hour calibration runtime.

Using the 96040A with other automation solutions

The 96040A is also integrated easily into existing automated systems and software. The time savings and efficiency gains offered by the 96040A can be realized by structuring test sequences to take full advantage of its “connect once measure many” capabilities.

The 96040A is designed to match or exceed the performance and functionality of the HP3335A and HP8662/3A in calibration systems. With HP3335A and HP8662/3A GPIB command emulation as standard, replacing these popular but obsolete and difficult-to-maintain products becomes just a plug-and-play substitution.

96040A summary specifications*
Frequency specifications Level specifications
(50 Ω output, see extended specifications for 75 Ω)
Range 1 mHz to 4 GHz -130 to +24 dBm to 125 MHz, 14 dBm at 4 GHz (leveled)
Resolution 10 µHz 0.001 dB
Accuracy ± 0.05 ppm ± 5 µHz Down to -48 dBm: ± 0.03 dB to 100 kHz, ± 0.05 dB to 128 MHz, ± 0.3 dB at 4 GHz
10 MHz to 128 MHz: ± 0.05 dB to -48 dBm, ± 0.1 dB to -84 dBm , ± 0.7 dB at -130 dBm
Attenuation ± 0.02 dB to 49 dB, ± 0.15 dB at 110 dB
Relative to +10 dBm, 10 Hz to 128 MHz
VSWR ≤ 100 MHz: ≤ 1.05, ≤ 2 GHz: ≤ 1.1, 2 GHz to 4 GHz: ≤ 1.0 + 0.05 xf (GHz)
Harmonics and spurious –60 dBc harmonics, –78 dBc spurious to 1 GHz
Phase noise at 1 GHz –144 dBc/Hz, typical, at 10 kHz to 100 kHz offset
Modulation AM, FM, PM, internal and external. Frequency pull and external leveling
Frequency sweep 1 mHz to 4 GHz. Linear or Logarithmic. Stop-Start or Center-Span
Frequency counter Internal 50 MHz frequency counter
Temperature Operating: 0 °C to 50 °C, 23 °C ± 5 °C for specified performance; Storage: -20 °C to +70 °C.
Standard interfaces IEEE-488.2 (GPIB)
GPIB command emulation 9640A, 9640A-LPN, 9640A-LPNX, HP3335, HP8662A, HP8663A.
Dimensions (HxWxD) 146 mm x 442 mm x 551 mm (5.8 in x 17.4 in x 21.7 in) including handles Industry-standard 19 in (483 mm) rack mounting when fitted with Y9600 rack mounting kit
Weight 18 kg (40 lb)
*Key specifications summary. Refer to the extended specifications for full and detailed specifications.

熱門產(chǎn)品
產(chǎn)品名稱參考價(jià)地區(qū)公司名稱更新時(shí)間 
艾德克斯ITECH 微功耗量測(cè)以及材料研究精密源表 IT2805 200V1.5A20W 面議 深圳市 深圳市賽儀歐電子有限公司 2025-02-13 在線詢價(jià)
自動(dòng)測(cè)量圖像尺寸設(shè)備 ¥560000 深圳市 深圳市中圖儀器股份有限公司 2024-08-11 在線詢價(jià)
羅卓尼克USB接口水活性快速測(cè)量探頭 面議 無(wú)錫市 無(wú)錫徽科特測(cè)控技術(shù)有限公司 2024-07-09 在線詢價(jià)
激光功率測(cè)量系統(tǒng) LPMS 面議 上海倍藍(lán)光電科技有限公司 2024-04-23 在線詢價(jià)
水分活度測(cè)量?jī)x廠商 面議 常州市 常州金壇泰納儀器廠 2024-08-29 在線詢價(jià)
防爆油箱油位測(cè)量裝置 面議 無(wú)錫市 無(wú)錫市興洲儀器儀表有限公司 2025-02-11 在線詢價(jià)
免責(zé)申明

所展示的信息由會(huì)員自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會(huì)員負(fù)責(zé),儀表網(wǎng)對(duì)此不承擔(dān)任何責(zé)任。儀表網(wǎng)不涉及用戶間因交易而產(chǎn)生的法律關(guān)系及法律糾紛,糾紛由您自行協(xié)商解決

友情提醒 :本網(wǎng)站僅作為用戶尋找交易對(duì)象,就貨物和服務(wù)的交易進(jìn)行協(xié)商,以及獲取各類與貿(mào)易相關(guān)的服務(wù)信息的平臺(tái)。為避免產(chǎn)生購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買相關(guān)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。過(guò)低的價(jià)格、夸張的描述、私人銀行賬戶等都有可能是虛假信息,請(qǐng)采購(gòu)商謹(jǐn)慎對(duì)待,謹(jǐn)防欺詐,對(duì)于任何付款行為請(qǐng)您慎重抉擇!如您遇到欺詐等不誠(chéng)信行為,請(qǐng)您立即與儀表網(wǎng)聯(lián)系,如查證屬實(shí),儀表網(wǎng)會(huì)對(duì)該企業(yè)商鋪?zhàn)鲎N處理,但儀表網(wǎng)不對(duì)您因此造成的損失承擔(dān)責(zé)任!

關(guān)于我們|網(wǎng)站導(dǎo)航|本站服務(wù)|會(huì)員服務(wù)|網(wǎng)站建設(shè)|特色服務(wù)|旗下網(wǎng)站|友情鏈接|在線投訴|興旺通|供應(yīng)信息

儀表網(wǎng)-儀器儀表行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺(tái)

Copyright ybzhan.cn All Rights Reserved法律顧問(wèn):浙江天冊(cè)律師事務(wù)所 賈熙明律師ICP備案號(hào):浙B2-20100369-24

客服熱線:0571-87756399,87759942加盟熱線:0571-87756399展會(huì)合作:0571-87759945客服郵箱:873582202@qq.com 投稿郵箱:ybzhan@qq.com

網(wǎng)站客服:服務(wù)咨詢:對(duì)外合作:儀表采購(gòu)群: 儀表技術(shù)群:

版權(quán)所有©浙江興旺寶明通網(wǎng)絡(luò)有限公司


提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個(gè)人信息: