Phynexus代理,Phynexus中國代理,Phynexus上海代理,Phynexus北京代理,Phynexus廣州代理,Phynexus代理,Phynexus,Phynexus代理,Phynexus
The Catalog lists part numbers for all of our standard products including columns with our standard resins: 6 standard affinity resins and gel filtration resin. In addition it lists our instrumentation products. We also have a custom resin program and can pack our PhyTip® columns with resin of your choice.
Plasmid DNA Purification
PhyNexus' Lysate Direct PhyTip® Columns for Plasmid DNA Purification utilizes silica-based chemistry in combination with our innovative pipette tip column format. Achieve reliable walk-away automation of plasmid DNA purification directly from cell pellets. Obtain >10 µg plasmid from up to 96 samples simultaneously, with purity suitable for sequencing, PCR, and transfections.
Affinity Columns
The unique design of the PhyTip® affinity columns allows bidirectional flow of the sample through the column to maximize the use of the resin by increasing capture and elution of the target protein, leading to the highest yield possible. The screens surrounding the resin at the base of the column allow elution volumes as low as 10µL, and therefore high concentration product. In addition, the high efficiency bidirectional washes lead to the highest possible sample purity. Perform affinity purification, ion exchange, desalting or buffer exchange applications.
Specialty Resins
BAC BV's CaptureSelect® media can now be efficiently processed via PhyNexus formatted in its PhyTip® system. By combining BAC BV's affinity resins, directed towards different epitopes on antibodies (Fc or VL, kappa or lambda), with PhyNexus' automated PhyTip®columns, we are able to offer a product to the market which enables researchers to purify antibodies and antibody fragments at very small scale in a high throughput mode. The highly specific CaptureSelect® resins in combination with the ease and small sample volumes needed for the PhyTip® columns makes the system extremely suitable during lead identification of antibodies and antibody fragments in drug discovery as well as for setting final chromatographic conditions for purification of identified leads either singly or in parallel with other potential leads or resins.
Gel Filtration Columns
PhyTip® gel filtration columns operate as small scale, chromatographic separation columns. They represent the only high throughput, automatable, chromatography desalting solution. The gel filtration columns are similar to the PhyTip® affinity columns in that the resin of choice is positioned between two inert screens that maintain the resin bed at the base of the column. Unlike the affinity columns, the sample is passed unidirectionally through the gel filtration columns by gravity flow. The gel filtration columns remove >95% of salts with >80% yield of protein, retain protein functionality, provide less than 10% CV for volume and concentration between final sample and provide functional protein that is ready for the downstream assay.
PhyScreen
Researchers often need to settle for the best results obtained from a few purification optimization steps. One of the benefits of a high throughput small-scale purification method is the ability to easily and quickly screen many purification options simultaneously. PhyNexus has made this even easier with the availability of the PhyScreen Ni-IMAC screen kit which includes columns of twelve different Ni-IMAC resins, prepared for ease of use with the MEA automated system, or other commercially available liquid handlers. Resin screening is especially valuable when affinity purifying His-tagged recombinant proteins due to the high propensity of background interactions between Ni-IMAC and naturally occurring multiple His residues.
Normal Phase Columns
PhyTip® Normal Phase Resin columns are designed for the specific enrichment of polar compounds. These PhyTip® columns are especially useful in oligosaccharide mapping and identification analysis of glycoproteins. High resolution tools such as HPLC and capillary electrophoresis are required for the separations of these complicated structures; however, detection must be enhanced through use of fluorescent dye labels. PhyTip® Normal Phase Resin columns are the perfect solution for high throughput, reproducible sample dye removal prior to identification and quantification.
Ion Exchange Columns
PhyTip® Ion Exchange columns offer the unique ability to screen different wash and elution buffers and a number of resins in a single experiment. Once ion exchange conditions have been optimized, they are directly transferable to larger manufacturing scale columns. Chromatographic separation is performed in a pipette tip column using back and forth flow to drive binding and release steps to equilibrium. Using the MEA 2 Personal Purification System enables 12 samples at a time to be processed. This can be increased to 96 samples with the use of robotic liquid handling systems. Four standard ion exchange resins are available in PhyTip® columns (strong anion, weak anion, strong cation, weak cation). For resin selection, the Ion Exchange Resin Screening Toolkit is a box of 96 tips containing 24 columns of each resin.
歡迎下載下面的資料以了解此產(chǎn)品的相關(guān)信息!預詢產(chǎn)品訂購信息
上海普邁生物致力于提供高質(zhì)量的產(chǎn)品和服務組織形態(tài)學研究與競爭力的產(chǎn)品
產(chǎn)品和服務,有相關(guān)產(chǎn)品的問題請直接
期貨每周下午5點前發(fā)定單,正常到上海時間為3-4周
現(xiàn)市區(qū)2天內(nèi)送到,外地以快遞為準
敬請關(guān)注!
:
:www.pumaibio.com
:pumaibio
:(直接客戶)
(經(jīng)銷商)
*etonbio、polysciences、Mattek、trevigen、Chromogenix、cyguns、IrvineScientific、Innovative Cell Technologies、enzo、novus、immunochemistry、eylabs、Polyplus、NIBSC、ALZET、hitobiotec、sutter instrument、mirus、StressMarq、Avanti、jena bioscience、Neuro Probe、tedpella、avanti、Rockland、CAYMAN、transgenomic、BioLegend、ambion、omicronbio、
Assaybiotech、chondrex、lc?laboratories、cosmobio、megazyme、NeoMarkers、BTI、eylabs、berryassoc、cellagentech、TOCRIS、Relia Tech、SouthernBiotech、Biosearch technology、Lumiprobe、StemCells?Inc、biovendor、NORGEN、alomone、jena?bioscience、Gracebio、Eurogentec、Gelcompany?、invitrogen、gene?bridges、MRC-Holland、laysanbio