TekConnect TCA系列適配器擴展了Tektronix高性能示波器的功能。與將信號從一個環(huán)境移動到另一個環(huán)境的傳統(tǒng)連接(如BNC到N或BNC到SMA)相比,該系列適配器系統(tǒng)提供了更好的性能和更少的信號失真。
關(guān)鍵性能規(guī)范
TCA75 – TekConnect-to-75 Ω BNC
- DC to ≥23 GHz (instrument dependent)
- VSWR – 1.1:1 (26.45 dB)
- 75 Ω input
- Auto Attenuation Factor Correction
TCA-BNC – TekConnect-to-TekProbe™ BNC 50 Ω
- DC to ≥4 GHz (instrument dependent)
- 50 Ω input (only)
- For control of TekProbe BNC (50 Ω) probes
TCA-N – TekConnect-to-N
- DC to ≥11 GHz (instrument dependent)
- 50 Ω input (only)
TCA-SMA – TekConnect-to-SMA
- DC to ≥18 GHz (instrument dependent)
- 50 Ω input (only)
TCA-292MM – TekConnect-to-2.92 mm
- DC to ≥25 GHz (instrument dependent)
- 50 Ω input (only)
- SMA compatible
TCA292D – TekConnect-to-2.92 mm
- DC to ≥33 GHz (instrument dependent)
- 50 Ω input (only)
- SMA compatible
TCA-1MEG
- DC to 500 MHz
- 1 MΩ input
TCA-VPI50
- DC to 4 GHz
- Use TekVPI Probes on MSO/DPO70000 Series Osilloscopes
- 50 Ω input (only)
Applications
- Signal integrity, jitter, and timing analysis
- Verification, characterization, and debug of sophisticated designs
- High-speed digital devices and circuits
- Semiconductor devices
- communications
- Investigation of transient phenomena
- Spectral analysis
- Video design and development
- HDTV and streaming digital video
TekConnect interface delivers superior signal fidelity, unparalleled versatility, and ease of use
The TekConnect interface ensures superior signal fidelity with useful bandpass up to 33 GHz, while offering unparalleled versatility with the world’s widest array of accessory signal acquisition solutions for high-performance, real-time oscilloscopes. This interface delivers a robust oscilloscope interface with multi-GHz analog bandwidths. The TekConnect interface preserves a low Voltage Standing Wave Ratio (VSWR) 50 Ω environment as well as a reliable electrical connection. A convenient, one-button release and locking mechanism provides quick, easy installation and removal of probes, amplifiers, and adapters.
TCA75 Adapter (75 to 50 Ω)
The TCA75 adapter allows Tektronix oscilloscopes with a TekConnect interface to easily access and measure 75 Ω terminated circuitry. The TCA75 attenuation factor is automatically corrected to provide the end user with correctly displayed signal magnitudes.
TCA-BNC Adapter (50 Ω only)
A direct 50 Ω input with TekProbe BNC 50 Ω capability, this adapter may be used as a direct 50 Ω BNC input or with Tektronix high-speed active and differential probes requiring the TekProbe BNC 50 Ω interface.
The TCA-BNC Adapter is a standard accessory with MSO/DPO 70000C/DX series oscilloscopes.
TCA-SMA and TCA-N Adapters (50 Ω only)
The high-speed SMA- and N-type adapters allow a more direct connection to the signal under test requiring N or SMA connections without losing performance by adding other external conversion adapters.
TCA-292D and TCA-292MM Adapters (50 Ω only)
These high-speed 2.92 mm-type adapters allow a more direct connection to the signal under test requiring a 2.92 mm connection without losing performance by adding other external conversion adapters. The locking screw must be used to ensure full bandwidth performance. The 2.92 mm connector is more robust and performs at higher frequencies than an SMA connector. The 2.92 mm connector is compatible with SMA connectors, but the electrical performance will be limited to the bandwidth of the SMA connector.
The TCA-292MM Adapter is a standard accessory with MSO/DPO 70000C series oscilloscopes and the TCA292D Adapter is a standard accessory with MSO/DPO 70000DX series oscilloscopes.
TCA-1MEG High-impedance Buffer Amplifier
The TCA-1MEG high-impedance buffer amplifier system extends the capabilities of Tektronix high-performance oscilloscopes, making them ideal for a variety of general-purpose measurements. The TCA-1MEG amplifier system provides a 1 MΩ path that is easily removed and replaced with a wide array of TekConnect probes, amplifiers, and adapters.
TCA-VPI50 TekVPI to TekConnect Probe Adapter
The TCA-VPI50 adapter extends the functionality of the TCA Series of adapters by enabling 50 Ω TekVPI probes to be used on oscilloscopes with TekConnect interfaces. The TCA-VPI50 will only work with 50 Ω terminated probes. It will not work with 1 MΩ terminated probes; examples of which are passive probes, current probes, and most high-voltage probes.
TekConnect adapters and probe compatibility
Tektronix offers a wide selection of probes with native TekConnect interfaces. For applications requiring a probe where there is not a TekConnect probe available, it is possible to use the TCA-1MEG, TCA-BNC, and TCA-VPI50 adapters to connect other Tektronix probes to your scope. This table lists probes that are known to be compatible with the TekConnect adapters.
Instrument input connection | TekProbe BNC 1 M?-to-TekConnect interface | TekProbe BNC 50 ?-to-TekConnect interface | |
Instrument input impedance | 1 M? / 10 pF | 50 Ω | |
Passive voltage probes | |||
1X | P6101B | NA | |
10X | P6139B | NA | |
Active voltage probes | |||
General | NA | P6245, P6243 | |
Differential voltage probes | |||
>2 GHz | NA | P6330 | |
<1.8 GHz <8 V Logic | NA | P6248, P6247, P6246 | |
Micro-volt | ADA400A | NA | |
High-voltage probes | |||
Differential | P5202A, P5205A, P5210A | P6251 | |
Single-ended | P5100A | NA | |
Current probes | |||
AC/DC <15 A | TCP2020 | NA | |
AC/DC 5 mA to 20 A | TCPA300, TCPA400 | TCPA300, TCPA400 | |
AC high-frequency | NA | CT6, CT2, CT1 | |
AC low-frequency | TRCP0300, TRCP0600, TRCP3000 | NA | |
O/E converter probes | NA | P6701B, P6703B |