The DLC Dynamic Load Compensation Systems is yet another state of the art innovation within temperature calibration. The DLC compensates for the negative effect on calibration accuracy that heat exchange between a dry-block calibrator and the sensor-under-test creates.
When a sensor is inserted into a dry-block calibrator, the sensor size (diameter and length) and the difference between calibration temperature and ambient temperature, create an axial gradient deviation inside the insert. Our temperature calibrators are already famous for their active dual-zone calibration principle, and the DLC takes this one step further, and now compensates inside the insert. The DLC, combined with an RTC Calibrator, creates the only dry-block that compensates for the heat dissipation caused by sensor loading.
• Control the lower section of the insert to within a few hundredths of a degree • The DLC indicator shows that the dual-zone is active and working • A DLC checkmark is present when temperature homogeneity is achieved • Save time by calibrating several sensors simultaneously • Calibrate large diameter sensors without losing accuracy • Aligning the thermos-sensitive part of the sensor is no longer needed
Options
DLC155 Differential TC type T. Probe length: 177 mm (6.96 in). Temperature range: -60 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
DLC158 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: -60 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
DLC159 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: -100 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
DLC250 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: 0 to 250°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
DLC700 Differential TC type T. Probe length: 230 mm (9.05 in). Temperature range: 0 to 700°C. Diameter: 4 mm (0.16 in) OD. Depth: 200 mm (7.9 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
RTC-156 -30 to 155°C (-22 to 311°F), Dry Block. Use DLC-155.
RTC-157 -45 to 155°C (-49 to 311°F), Dry Block. Use DLC-155.
RTC-158 -22 to 155°C (-8 to 311°F), Dry Block / Liquid Bath. Use DLC-158.
RTC-159 -100 to 155°C (-148 to 311°F), Ultra Cooler. Use DLC-159.
RTC-250 28 to 250°C (82 to 482°F), Dry Block / Liquid Bath. Use DLC-250.
RTC-700 33 to 700°C (91 to 1292°F), Dry Block. Use DLC-700
Software
Con50 Con50 (Free) - Provides a way to configure and calibrate smart sensors for the DTI050 and the RTC / PTC temperature calibrators.
Accessories
127312 Calibration Insert for DLC155
124897 Calibration Insert for DLC158
128477 Calibration Insert for DLC159
127759 Calibration Insert for DLC250
127149 Calibration Insert for DLC700
127587 Pt100 calibration reference probe, 3 mm diameter
STS200A970 Pt100 calibration reference probe, 4 mm diameter for DLC700