間隙隔爆原理一體化防爆熱電阻工作原理
一體化防爆熱電阻利用間隙隔爆原理,當(dāng)腔內(nèi)發(fā)生爆炸時(shí),能通過(guò)接合面間隙熄火和冷卻,使爆炸后的火焰的溫度傳不到腔外,從而進(jìn)行測(cè)溫。熱電偶(阻)生產(chǎn)的熱電勢(shì)(電阻)經(jīng)過(guò)溫度變送器的電橋產(chǎn)生不平衡信號(hào),經(jīng)放大后轉(zhuǎn)換成為4~20mA的直流電信號(hào)給工作儀表,工作儀表便顯示出所對(duì)應(yīng)的溫度值
間隙隔爆原理一體化防爆熱電阻測(cè)溫范圍及允差(熱電偶)
型號(hào) | 分度號(hào) | 允許誤差與偶材等級(jí) | |||
I級(jí) | II級(jí) | ||||
允差值 | 測(cè)溫范圍℃ | 允差值 | 測(cè)溫范圍℃ | ||
WRNB | K | ±1.5℃ | -40~+375 | ±2.5℃ | -40~+333 |
±0.004│t│ | 375~1000 | ±0.0075│t│ | 333~1200 | ||
WRMB | N | ±1.5℃ | -40~+375 | ±2.5℃ | -40~+333 |
±0.004│t│ | 375~1000 | ±0.0075│t│ | 333~1200 | ||
WREB | E | ±1.5℃ | -40~+375 | ±1.5℃ | -40~+333 |
±0.004│t│ | 375~800 | ±0.004│t│ | 333~900 | ||
WRFB | J | ±1.5℃ | -40~+375 | ±1.5℃ | -40~+333 |
±0.004│t│ | 375~750 | ±0.004│t│ | 333~750 | ||
WRCB | T | ±1.5℃ | -40-~+125 | ±1℃ | -40~+333 |
±0.004│t│ | 125~350 | ±0.0075│t│ | 133~350 | ||
WRPB | S | ±1℃ | 0~+1100 | ±2.5℃ | 0~600 |
±[1+0.003(t-1100)] | 1100~1600 | ±0.0025│t│ | 600~1600 |
間隙隔爆原理一體化防爆熱電阻
熱響應(yīng)時(shí)間
當(dāng)溫度出現(xiàn)階躍變化時(shí),儀表的電流輸出信號(hào)變化至相當(dāng)于該階躍變化的50%所需的時(shí)間,通常以τ0.5表示當(dāng)溫度變送器的階躍響應(yīng)穩(wěn)定時(shí)間不超過(guò)熱電偶(阻)熱響應(yīng)穩(wěn)定時(shí)間τ0.5的五分之一時(shí),則用熱電偶(阻)熱響應(yīng)時(shí)間作為儀表的熱響時(shí)間;
當(dāng)溫度變送器的階躍響應(yīng)穩(wěn)定時(shí)間不超過(guò)熱電偶(阻)熱響應(yīng)穩(wěn)定時(shí)間τ0.5的二分之一時(shí),則用溫度變送器熱響應(yīng)時(shí)間作為儀表的熱響應(yīng)時(shí)間。
基本誤差
儀表的基本誤差應(yīng)不超過(guò)熱電偶(阻)和溫度變送器基本誤差的合成誤差。