型號(hào)分度號(hào)測(cè)溫范圍 ℃公稱壓力流速規(guī)格 Lxl
WRN-01T
WRN2-01TK0-800≤ 30MPa≤ 100m/s——
WRE-01T
WRE2-01TE0-600
WZP-01T
WZP2-01TPt100-200-+500
WRN-624
WRN2-624K0-800≤ 30MPa≤ 80m/s絕緣式
WRE-624
WRE2-624E0-600
WZP-624
WZP2-624Pt100-200-+500
WRN-625
WRN2-625K0-800接殼式
WRE-625
WRE2-625E0-600
WRN-012T
WRN2-012TK0-800≤ 10MPa——440x230
640x430
840x630
1340x1130
2500x1200
640x430
3000x1500
3500x1700
WRE-012T
WRE2-012TE0-600
WZP-012T
WZP2-012TPt100-200-+500
WRN-12AT
WRN2-12ATK0-800
WRE-12AT
WRE2-12ATE0-600
WZP-12AT
WZP2-12ATPt100-200-+500
WRN-013T
WRN2-013TK0-800≤ 30MPa≤ 100m/s380x50
430x100
480x150
WRE-013T
WRE2-013TE0-600
WZP-013T
WZP2-013TPt100-200-+500
WRN-014T
WRN2-014TK0-800≤ 10MPa≤ 80m/s280x50
330x100
380x150
430x200
480x250
530x300
WRE-014T
WRE2-014TE0-600
WZP-014T
WZP2-014TPt100-200-+500
WRN-015T
WRN2-015TK0-800≤ 10MPa___280x50
330x100
380x150
430x200
480x250
530x300
580x350
630x400
2安裝要求編輯對(duì)熱電阻的安裝,應(yīng)注意有利于測(cè)溫準(zhǔn)確,安全可考及維修方便,而且不影響設(shè)備運(yùn)行和生產(chǎn)操作.要滿足以上要求,在選擇對(duì)熱電阻的安裝部位和插入深度時(shí)要注意以下幾點(diǎn):
1、為了使熱電阻的測(cè)量端與被測(cè)介質(zhì)之間有充分的熱交換,應(yīng)合理選擇測(cè)點(diǎn)位置,盡量避免在閥門,彎頭及管道和設(shè)備的死角附近裝設(shè)熱電阻.
2、帶有保護(hù)套管的熱電阻有傳熱和散熱損失,為了減少測(cè)量誤差,熱電偶和熱電阻應(yīng)該有足夠的插入深度:
(1)對(duì)于測(cè)量管道中心流體溫度的熱電阻,一般都應(yīng)將其測(cè)量端插入到管道中心處(垂直安裝或傾斜安裝).如被測(cè)流體的管道直徑是200毫米,那熱電阻插入深度應(yīng)選擇100毫米;
(2)對(duì)于高溫高壓和高速流體的溫度測(cè)量(如主蒸汽溫度),為了減小保護(hù)套對(duì)流體的阻力和防止保護(hù)套在流體作用下發(fā)生斷裂,可采取保護(hù)管淺插方式或采用熱套式熱電阻.淺插式的熱電阻保護(hù)套管,其插入主蒸汽管道的深度應(yīng)不小于75mm;熱套式熱電阻的標(biāo)準(zhǔn)插入深度為100mm;
(3)假如需要測(cè)量是煙道內(nèi)煙氣的溫度,盡管煙道直徑為4m,熱電阻插入深度1 m即可.
(4)當(dāng)測(cè)量原件插入深度超過1m時(shí),應(yīng)盡可能垂直安裝,或加裝支撐架和保護(hù)套管.