The USB2000+ Series of Spectrometers from Ocean Optics feature an amazingly small footprint, plug-and-play capabilities and a simplified interface that operates without external power. Simply plug your USB2000+UV-VIS or VIS-NIR into an available USB port on your computer and you eliminate the need for analog converters. Your spectrometer comes preconfigured to the 200-850 nm wavelength range for USB2000+UV-VIS or 350-1100 nm for the USB2000+VIS-NIR. Both models include a proprietary multi-bandpass order sorting filter. Our USB2000+UV-VIS also features a UV2 detector coating upgrade. Our ES (Enhanced Sensitivity) models feature an installed detector collection lens for increased light collection efficiency. |
|
Ready to Roll!
Both the USB2000+UV-VIS and USB2000+VIS-NIR Series Spectrometers are in stock and ready to ship to you today. These small but durable spectrometers are covered by Ocean Optics' exclusive 3-Year Warranty
Under the Hood
USB2000+ | USB2000+ | USB2000+ | USB2000+ | |
Computer Interface: | -- Universal Serial Bus (RS-232 available on side connector) -- | |||
Spectrometer channels: | -- Master spectrometer channel only -- | |||
Detector: | -- 2048-element linear silicon CCD array -- | |||
Integration time: | -- 1 ms - 65 seconds -- | |||
Useable range: | 200-850 nm (grating-dependent) | 350-1000 nm (grating-dependent) | 200-850 nm (grating-dependent) | 350-1000 nm (grating-dependent) |
Dynamic range: | -- 8.5 x 107 (system); 1300:1 (single acquisition) -- | |||
Sensitivity: | -- 75 photons/count; also, 2.9 x 10-17 joule/count -- -- 2.9 x 10-17 watts/count (for 1-second integration) -- | |||
Signal-to-noise ratio: | -- 250:1 (at full signal) -- | |||
Dark noise: | -- 50 (RMS) -- | |||
Grating: | 600 lines/mm, set to 200-850 nm (blazed at 300 nm) | 600 lines/mm, set to 350-1000 nm (blazed at 500 nm) | 600 lines/mm, set to 200-850 nm (blazed at 300 nm) | 600 lines/mm, set to 350-1000 nm (blazed at 500 nm) |
Slit: | -- 25 μm width (height is 1mm) -- | |||
Detector collection lens: | No | No | Yes | Yes |
Focal length: | -- 42 mm (input); 68 mm (output) -- | |||
Order-sorting: | Single-piece, multi-bandpass detector coating to eliminate second-order effects from 200-850 nm | Single-piece, multi-bandpass detector coating to eliminate second-order effects from 350-1000 nm | Single-piece, multi-bandpass detector coating to eliminate second-order effects from 200-850 nm | Single-piece, multi-bandpass detector coating to eliminate second-order effects from 350-1000 nm |
Resolution: | -- 1.5 nm (FWHM) -- | |||
Stray light: | < 0.05% at 600 nm | < 0.05% at 600 nm | < 0.05% at 600 nm | < 0.05% at 600 nm |
Fiber optic connector: | -- SMA 905 to single-strand optical fiber (0.22 NA) -- |