Bandwidth
DC to ≥20 MHz (-3 dB). Derate with frequency. See Figure 1. (Calculated from Rise Time BW = .35/Rise Time)
Rise time
≤17.5 ns
Max RMS current
150 A
Max peak pulse current
500 A
Minimum sensitivity
5 mA (on oscilloscope's 1 mV/div setting)
AC coupling (on oscilloscopes that support AC/DC coupling)
Current ranges
25 A and 150 A
Max bare-wire voltage
600 VRMS CAT I and II
300 VRMS CAT III
TYPICAL CHARACTERISTICS
DC accuracy
±1% typical (3% warranted)
Max amp-second product
25 A range
3,000 aµs
150 A range
15,000 aµs
Insertion impedance
0.03 Ω at 1 MHz
0.075 Ω at 5 MHz
.125 at 10 MHz
.3 at 20 MHz
Signal delay
≈ 21 ns
Displayed RMS noise
≤500 μARMS (probe only)
PHYSICALCHARACTERISTICSCONTAINER
Cable length
2 meters (79 in.)
Probe head size
Length
26.8 cm (10.55 in.)
Width
4.1 cm (1.6 in.)
Height
15.6 cm (6.13 in.)
Max conductor diameter
21 mm x 25 mm (0.83 in. x 1.0 in.)
Shipping weight
.7865 kg (1.734 lb.)
Power requirements
TCP0150 is powered directly by oscilloscopes with the TekVPI interface
ENVIRONMENTAL
Temperature
Operating
0 ºC to +50 ºC
Nonoperating
-40 ºC to +75 ºC
Humidity
Operating
5% to 95% RH (Relative humidity) at up to +30 ºC
5% to 85% RH above 30 ºC up to +50 ºC, noncondensing
Nonoperating
5% to 95% RH (Relative humidity) at up to +30 ºC
5% to 85% RH above 30 ºC up to +75 ºC, noncondensing
Altitude
Operating
Up to 2,000 meters (6,560 feet)
Nonoperating
Up to 12,000 meters (40,000 feet)