530L流量校準(zhǔn)器Bios Defender 530-Low Flow
的詳細(xì)介紹流量校準(zhǔn)器Defender 510/520/530 儀器介紹:
Defender 510/520/530是新一代的干式氣體流量計(jì),它是一級(jí)流量計(jì),并被眾多的個(gè)體采樣泵廠商*和配套使用??捎糜诠I(yè)衛(wèi)生、環(huán)保領(lǐng)域和各類實(shí)驗(yàn)室。它采用干式活塞運(yùn)動(dòng)的原理,一次按鍵即可產(chǎn)生連續(xù)多個(gè)讀數(shù)。與傳統(tǒng)的泡沫式流量計(jì)相比,使用更加方便快速。520型號(hào)比510增加了同時(shí)測(cè)試溫度和壓力的功能。
流量校準(zhǔn)器Defender 510/520/530 主要特點(diǎn):
- 采用干式活塞原理,使用簡(jiǎn)單方便
- 流量精確控制,經(jīng)過ISO17025認(rèn)證
- 結(jié)構(gòu)緊湊
- 寬大顯示屏幕
- 每組讀數(shù)高達(dá)100個(gè)
- 可內(nèi)置溫度、壓力傳感器,優(yōu)化測(cè)試結(jié)果(520系列)
型號(hào) | Defender 510 | Defender 520 | Defender 530 | ||
流量范圍 | 510L, 5-500ml/min 510M, 50-5000ml/min 510H, 300-30,000ml/min | 520L, 5-500ml/min 520M, 50-5000ml/min 520H, 300-30,000ml/min | 530L, 5-500ml/min 530M, 50-5000ml/min 530H, 300-30,000ml/min | ||
流量精度 | 1% | 1% | 1% | ||
標(biāo)準(zhǔn)的精度 | N/A | N/A | 1.2% | ||
可選 測(cè)量 單位 | 流量 | mL/min, L/min, cc/min, cf/min | mL/min, L/min, cc/min, cf/min | mL/min, L/min, cc/min, cf/min | |
標(biāo)準(zhǔn)化 | N/A | N/A | smL/min, sL/min, scc/min, scf/min | ||
溫度 | N/A | ℃ ℉ | ℃ ℉ | ||
壓力 | N/A | mmHg, PSI, kPa | mmHg, PSI, kPa | ||
溫度和壓力傳感器 | No | Yes | Yes | ||
壓力 | N/A | 3.5 mmHg (典型) 7.0 mm (zui大) | 3.5 mmHg (典型) 7.0 mm (zui大) | ||
溫度 | N/A | 0.8℃ (典型) 1.3℃ (zui大) | 0.8℃ (典型) 1.3℃ (zui大) | ||
每次讀數(shù)時(shí)間 | 1~15 秒 | ||||
讀數(shù)模式 (選擇從1到100次測(cè)量的平均值) | 單次 (手動(dòng)), 連續(xù)或突發(fā)模式 | ||||
氣體兼容性 | 吳腐蝕性氣體、不結(jié)露氣體, 濕度小于70% | ||||
流動(dòng)模式 | 壓迫或抽吸 | ||||
測(cè)量單元 | 一體式 | ||||
AC 交流直流變換器/充電器 | 12V DC, > 250ma, 2.5mm中心位置 | ||||
Battery System電池類型 | 6V 可充電密封鉛酸蓄電池,典型工作時(shí)間6~8 小時(shí) | ||||
電池運(yùn)行時(shí)間 (5 次/分鐘) | 背景光打開3小時(shí), 背景光關(guān)閉 8小時(shí) | ||||
壓入或抽吸附件 | 軟管 | ||||
操作壓力 () | 15 PSI | ||||
顯示 | 帶背光的圖形LCD液晶顯示器 | ||||
數(shù)據(jù)端口 (使用優(yōu)化軟件) | RS-232串口 | ||||
數(shù)據(jù)電纜 (使用優(yōu)化軟件) | 1 米 Defender校準(zhǔn)器至電腦的串口 | ||||
防護(hù)箱 | 軟質(zhì)或硬質(zhì)儀器箱 | ||||
尺寸(H x W x D) | 5.5”x6”x3”/140x150x75mm | ||||
重量 | 29oz/820g | ||||
服從:RoHS-和CE |
Bios Defender 530 Calibrator -- Coming January 2010
The Bios Defender 530, with the ability to take both volumetric and standardized readings, is the latest addition to the popular Defender 510 and 520 line of Bios DryCal primary flow calibrators. Automatic correction of readings for temperature and pressure, rather than merely recording of ambient conditions, is essential for many applications.
The Defender 530, like the other instruments in the line, provides users with a true primary flow calibrator for industrial hygiene, environmental and laboratory applications. The design offers low cost, light weight and ultra-compact size, incorporating the highly-regarded DryCal technology. It is small enough to fit easily into a slim briefcase for convenient transport.
Like all Bios calibrators, the Defender 530 is easy to use. Turn it on. Connect it to a sampling pump. Start taking readings. It's as simple as that. Calibrations within a minute with no messy soap bubble solutions.
The Defender 510, 520 and 530 can take hands-free continuous readings while quickly and accuray setting the flow rate on air sampling pumps or other instruments. The Defender 510/520/530 calibrators connect to any PC and pre- and post-calibration data can be downloaded with the included Integrator 110 with the Optimizer Collect Light software.
Bios Defender 530 Specifications
Size 5.5"H x 6"W x 3"D
140 mm x 150 mm x 75 mm Weight 29 oz. / 820 g Flow Ranges
DryCal Defender Low (L) Flow: 5 to 500 ccm DryCal Defender Medium (M) Flow: 50 - 5,000 ccm DryCal Defender High (H) Flow: 300 - 30,000 ccm Accuracy
Volumetric ±1.0% Standardized ±1.2% User-Selectable Measurement Units Volumetric Flow mL/min, L/min, cc/min, cf/min Standarized Flow smL/min, sL/min, scc/min, scf/min Pressure mmHg, PSI, kPa Temperature ºC, ºF Readings Approximate Time per Reading 1-15 seconds Reading Styles Single (manual), Continuous or Burst, with averaging function user-selectable from 1 to 100 measurements Gas Compatibility Use with non-corrosive, non-condensing, non-combustible gases, less than 70% humidity Flow Modes Suction or Pressure Measurement Cell Style Integrated Temperature & Pressure Sensors In the flow stream
Press: 3.5 mmHg (typical), 7.0 mm (max)
Temp: 0.8 °C (typical) 1.3 °C (max) Battery System AC Adapter/Charger 12 DC, >250 ma, 2.5 mm, center positive Battery 6V rechargeable, sealed lead-acid, 6-8 hours typical operation Battery Operational Time (5 cycles/min), 3 hours backlight on, 8 hours backlight off Pressure & Suction Fittings ¼” ID Hose Barb Display Backlit graphical LCD Storage Temperature 0-70 °C Ambient Humidity 0-70% - non-condensing Operating Pressure (Absolute) 15 PSI Warranty Instrument: 1 year, Battery: 6 months Data Port
Serial RS-232 (for use with Optimizer Collect software) Data Cable 1 meter (Defender Data Port to PC Serial Port) Protective Case Soft side or Pelican cases available Laboratory Accreditation Backed by ISO 17025 accreditation by NVLAP of NIST Instrument Certification RoHS and CE Compliant
Bios Defender 500 Kits Include: One flow cell, Bios Optimizer 110 PC Serial Cable, Software CD, AC Power Adapter/Charger, Plastic Leak Test Caps (2), NIST-Traceable Calibration Certificate and Mini-Manual.
Bios Integrator 110 and Optimizer Collect Software
The Defender 510/520 and the Defender 530 come standard with the Bios Integrator 110 and Optimizer Collect Light software for bullet-proof transfer of an ASCII text file of the flow data into an Excel® spread sheet with automatic recording and graphing of flow measurements.
The Optimizer Collect software helps to meet the needs of ISO, TQM, or occupational health and safety management systems by providing a secure audit trail for all pump calibrations, regardless of the pump type or manufacturer.
The basic Bios Optimizer Collect Light allows users to download data directly to a Microsoft Excel® preconfigured Spreadsheet.for easier collection, storage and record-keeping.
Enter flow rates from pumps or other flow source and calibrate the flow source. Data is recorded directly to a preconfigured Microsoft Excel® Spreadsheet.
Enter flow data from a flow meter and capture and compare the flow measurements from tje Bios DryCal precision calibrator into a preconfigured Microsoft Excel® Spreadsheet.
Optiimizer Collect light is upgradeable to a full version of Collect by purchasing an Activation code from Bios for automatic multi-point calibration of MFC/MFM using DryCal and Integrator 110.
The upgrade to the Bios Optimizer Collect full version allows the user to not only capture, but secure, organize, search and present data. It stores the records in a small but secure SQL database. These records can also be easily opened in a variety of off-the-shelf database applications, including Microsoft Excel and Access.
The Bios Defender - Overview
Accuracy
- Proven percent of reading accuracy is supported by ISO 17025 accreditation by NVLAP of NIST
- Integrated temperature sensors and pressure transducers placed directly in the flow stream for optimum standardized results.
Convenience
- Housed in a molded case with rubber handgrips for a better feel and a sleeker, more contemporary look
- Large illuminated flow cell viewing window
- Navigation menu and a large, illuminated graphical display with zoom feature
- Rated for extreme cold operation, down to -20 ºC
- RoHS (Restriction of Hazardous Substances) compliant for Europe
- Automatic Shutoff
Flexibility
- Choose between flow units
- – Volumetric: mL/min, L/min, cc/min, or cf/min
- Standardized: smL/min, L/min, cc/min, scf/min
- Include up to one hundred readings in a group average
- Take individual readings, continuous hands-free readings, or set to read in time intervals anywhere from one minute to sixty minutes between readings
- Available in three models for application expansion. Use the
- Bios Defender 510 to calibrate personal air samplers and other volumetric instruments;
- Bios Defender 520 "three-in-one" to calibrate volumetric instruments, record ambient temperature and pressure conditions for the audit trail, or to calibrate devices that read in mass flow;
- Bios Defender 530, for both volumetric flow readings or standarized readings, which correct for temperature and pressure, or to calibrate devices that read in mass flow,.
Software:
- The Integrator 110 and Optimizer Collect Light software is bundled with the Defender with an integrated serial PC interface for easy transfer of flow data to a text file, with automatic recording and graphing of flow measurements.
- The upgrade to the Bios Optimizer Collect Full version allows the user to not only capture, but secure, organize, search and present data. It stores the records in a small but secure SQL database. These records can also be easily opened in a variety of off-the-shelf database applications, including Microsoft Excel and Access.