運(yùn)動(dòng)黏度測(cè)試儀
KV3000/KV4000運(yùn)動(dòng)黏度測(cè)試儀 | |||||||||||||||||||||||||||||||||||
KV3000&KV4000運(yùn)動(dòng)粘度浴(帶集成數(shù)字計(jì)時(shí)器)簡(jiǎn)介 在規(guī)劃和選擇廣泛的石油產(chǎn)品過(guò)程中,運(yùn)動(dòng)粘度是一個(gè)重要的基本指標(biāo)。精確控溫的毛細(xì)管粘度計(jì),常常用于測(cè)量液體在重力或真空條件下的流動(dòng)。 運(yùn)動(dòng)黏度測(cè)試儀 技術(shù)規(guī)范 運(yùn)動(dòng)黏度測(cè)試儀 包括的附件:
| |||||||||||||||||||||||||||||||||||
KV3000/KV4000 Kinematic Viscosity Baths | |||||||||||||||||||||||||||||||||||
New constant temperature bath series with advanced temperature control circuitry and integrated timing features for convenient, accurate glass capillary viscometry determinations. Microprocessor PID circuitry assures precise, reliable temperature control within ASTM specified tolerances throughout the operating range of the bath. Simple push-button controls and dual digital displays permit easy setting and monitoring of bath temperature. Two place calibration offset capability is provided. Baths accommodate seven glass capillary viscometers of various types. Viewing the viscometers is made easy by glare-free fluorescent illumination inside the bath and a baffle that provides a background for easy viewing. Temperature control uniformity is assured by means of motorized stirrer which provides complete circulation without turbulence. Connection of the built-in cooling coil to tap water or a recirculating water chiller facilitates temperature control at ambient or below ambient temperatures. Communications software (RS232, etc.) ramp-to-set, and other enhanced features are available at additional cost. Contact your Koehler Customer Service representative for more information. Integrated Timing Features — KV3000 incorporates seven digital timers on the front control panel for convenient timing and monitoring of the efflux interval for each viscometer. On KV4000, the user can enter the viscosity constant for each viscometer on the front LCD control/display, and then get the test result in both efflux time and viscosity units automatically after stopping each timer. All timing functions on both models are displayed in 0.1 second resolution and are accurate within 0.01%. Bath Construction and Safety Features — Bath chamber is a clear Pyrex vessel enclosed in a polyester-epoxy finished steel housing. Top working surface has seven 2" (51mm) viscometer ports and is constructed of stainless steel for easy cleaning. Front viewing window assures safe, distortion-free viewing. Microprocessor temperature controller incorporates safety circuitry that interrupts power to the heaters in the event of an overtemperature condition or disconnection of the primary probe. For added safety, a redundant adjustable controller with separate sensor probe interrupts power if an overtemperature situation occurs. An integrated low-liquid sensor prevents operation of the bath if the bath liquid is not filled to the proper level, and cuts off power should it fall below during operation. Both overtemperature and low liquid level circuits will latch and prevent further operation of the bath until the fault is removed. Bath rests on adjustable leveling feet. All electronics are mounted on a sliding tray for easy access. Includes thermometer holder and seven plastic port covers with handles. Specifications Conforms to: ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550; FTM 791-305; NF T 60-100 Temperature Range: ambient to 150°C (302°F); –20°C to 150°C (–4°F to 302°F) with an external chiller Temperature Display: 0.1°C/0.1°F resolution, calibrate to 0.01°C/0.01°F Temperature Control Accuracy and Uniformity: Exceeds ASTM requirements throughout the operating range |