測量原理 | 電磁開關(guān) |
產(chǎn)品標(biāo)題 | The flowmeter for highest medium temperatures with a compact, easily accessible transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. |
傳感器特點 | Versatile applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross-section constriction. Maintenance-free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. |
變送器特點 | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. |
公稱口徑范圍 | DN 15 to 600 (? to 24") |
接液部件材質(zhì) | Liner: PFA; PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium; Duplex 1.4462 (UNS S31803) |
測量變量 | Volume flow, conductivity, mass flow |
測量誤差 | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) |
測量范圍 | 4 dm3/min to 9600 m3/h (1 gal/min to 44 000 gal/min) |
過程壓力 | PN 40, Class 300, 20K |
介質(zhì)溫度范圍 | Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
環(huán)境溫度范圍 | Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
傳感器外殼材質(zhì) | DN 15 to 300 (? to 12""): AlSi10Mg, coated DN 350 to 600 (14 to 24""): Carbon steel with protective varnish |
變送器外殼材質(zhì) | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design |
防護等級 | Standard: IP66/67, Type 4X enclosure Option: IP69 |
顯示/操作 | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
輸出 | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
輸入 | Status input 4-20 mA input |
數(shù)字式通信 | HART, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA |
電源 | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
危險區(qū)認(rèn)證 | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
產(chǎn)品安全性 | CE, C-tick, EAC marking |
功能安全性 | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
計量認(rèn)證和證書 | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TüV-attestation) |
壓力認(rèn)證和證書 | PED, CRN |
船級證書 | 3.1 material |
衛(wèi)生型認(rèn)證和證書 | ACS, NSF 61 |