行程范圍(mm) Measuring Strokes | 外形尺寸(mm) Overall Dimension | 主機(jī)重量 (Kg) Machine Weight | 被測工件重量 (Kg) Max. Part Weight | |||||
X | Y | Z | Lx | Ly | Lz | |||
800 | 1000 | 600 | 1350 | 1935 | 22729 | 1074 | 500 | |
精度指標(biāo):(根據(jù)ISO10360-2坐標(biāo)測量機(jī)的性能評(píng)定標(biāo)準(zhǔn))(Accuracy is according to ISO 10360 – 2) | ||||||||
允許示值誤差MPEE (mm) Maximum permissible error of indication of a CMM for size measurement (mm) | 允許探測誤差MPEP (mm) Maximum permissible Probing Error (mm) | |||||||
2.8+L/300 | 3.5 | |||||||
動(dòng)態(tài)性能Dynamic Performance | ||||||||
3D運(yùn)動(dòng)速度(mm/s) 3D positioning speed | 3D運(yùn)動(dòng)加速度(mm/s2) 3D acceleration | |||||||
520 | 1730 |
測量機(jī)室溫度要求:Room Required Specifications | |
房間溫度 (溫控間) Room Temperature | 18~ |
溫度梯度(時(shí)間) Temperature Gradient (in time) | |
溫度梯度(時(shí)間) Temperature Gradient (in time) | |
溫度梯度(空間)Temperature Gradient (in the volume) | |
測量機(jī)室濕度要求:Humidity Required Specifications | |
空氣相對(duì)濕度 Relative humidity | 45-75% |
氣源要求:Air Supply System Required Specifications | |
最小供氣壓力 Min. air pressure | 7bar [0.7 MPa] |
耗氣量Air consumption | 180 NL/min |
電源要求:Electrical requirements | |
電壓Voltage | 220 V ± 10% |
頻率Frequency | 50/60 Hz |
電流Current | |
用電設(shè)備要求接地可靠:接地電阻小于4歐姆 A good earth ground (less than 4 W) is required for reliable operation of the electrical controls. |