For continuous monitoring of any combination of heat treat atmosphere gases such as Oxygen (O2), Methane (CH4), Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrogen (H2), Ammonia (NH3), and Dew Point (standard and low ranges). Also available for other industrial process gases.
Results per Page :
Results 1 - 22 of 22
1
Item #
Enclosure and Mounting Details
Resolution
Response Time (T-90)
Power
Analyzer Type
Hazardous Area Rating Options
Model 7900N4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7901AN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Carbon Monoxide only (or as Combustibles = CO x 2), Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7901BN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Hydrogen only, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7901CN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Combustibles only (as CO + H2, catalytic type with air make-up), Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7901DN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Methane only, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7901EN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Carbon Dioxide only, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7902AN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Carbon Monoxide & Carbon Dioxide, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7902BN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Carbon Monoxide & Hydrogen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7902CN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Carbon Monoxide & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7902DN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Oxygen & Carbon Dioxide, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7902EN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Oxygen & Hydrogen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7902FN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Oxygen & Methane (Hydrogen & Carbon Dioxide), Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7903AN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Methane, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7903BN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Hydrogen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7903CN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7903DN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Methane, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7903EN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Hydrogen, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7904AN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 4 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, Methane, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7904BN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 4 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, Hydrogen, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7904CN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 4 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, Methane, & Hydrogen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7904DN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 4 Gas Analyzers, Carbon Monoxide, Methane, Hydrogen, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating
0.1%, 1 PPM, 1°F (Dew Point)
20-30 seconds to 90% step change
115 VAC, 60 Hz 220 VAC, 50 Hz
CO Analyzer
General Purpose, Non-Hazardous
Model 7905AN4
Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 5 Gas Analyzer, Carbon Monoxide, Carbon Dioxide, Methane, Hydrogen, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating