simpson2173,simpson2174,simpson2182AC電流表頭
simpson2173,simpson2174,simpson2182,simpson2183,simpson2184,
simpson2121,simpson2121T,simpson2152,simpson2122,simpson2122T,
simpson2142,simpson2153,simpson2123,simpson2123T,simpson2143,
simpson2154,simpson2124,simpson2124T,simpson2144表盤式表頭,品牌:辛普森simpson,
simpson century style analog panelmeter表盤式表頭,
- Rugged black phenolic case
- Glass window for optimum viewing
Accuracy
Movement
Suspension
Tracking
Shielding
Response Time
Overload (1 sec.)
Overload
(Continuous)
Repeatability
Dial
Resistance
Operating
Temperature
Case
Pointer
Scale Length
Net Weight
±2% F.S.; Compensated Meters: ±3% F.S.
Dynamometer
Pivot and jewel
±3%
Calibration is unaffected by magnetic panel
mounting.
1.5 seconds maximum
10 times F.S.
1.5 times F.S.
2%
Each dial arc is calibrated to track thespecific
type of movement used.
±15% of meter impedance
-4°F to +149°F (-20°C to +65°C)
High density black plastic
Knife-edge, with black matte finish
Model 2173: 2.48” (63.0mm)
Model 2174: 3.68” (93.5mm)
Model 2173: 9oz (0.26kg)
Model 2174: 13oz (0.37kg)
Frequency Meter Specifications
Accuracy
Movement
Suspension
Tracking
Shielding
Center Scale Value
Power Consumption
Max. Input Voltage (10 sec)
Dial
Operating Temperature
Case
Pointer
Scale Length
Net Weight
Warm-up Time
45-55Hz ±0.3Hz (120V-240V)
55-65Hz ±0.3Hz (120V-240V)
380-420Hz ±1.2Hz (120V-240V)
Small core magnet, self-shielding
Pivot and jewel
±3%
Calibration is unaffected by magnetic panelmounting.
50/60/400Hz
1.6VA
150, 120V normal
280, 240V normal
Each dial arc is calibrated to track thespecific
type of movement used.
-4°F to +149°F (-20°C to +65°C)
High density black plastic
Knife-edge, with black matte finish
Model 2182: 1.88” (47.2mm)
Model 2183: 2.48” (63.0mm)
Model 2184: 3.68” (93.5mm)
Model 2182: 5oz (0.14kg)
Model 2183: 6oz (0.17kg)
Model 2184: 9oz (0.26kg)
5 minutes
Specifications for other meters
Accuracy
Movement
Suspension
Tracking
Shielding
Response Time
Overload (1 sec.)
Overload (Continuous)
Repeatability
Dial
Resistance:
Operating Temperature
Case
Pointer
Scale Length
Net Weight
±2% F.S. Iron Vane, +3% F.S. Rectified
Models 2152, 2153, 2154: Iron-vane,magnetically
damped. 2121 and 2121T: small core
magnet, all others Annular, self-shielding
Pivot and jewel except for “T” models which
have taut band movement
±3%
Calibration is unaffected by magnetic panel
mounting.
1.5 seconds maximum
10 times F.S.
1.5 times F.S.
2% pivot and jewel, 0.5% taut band
Each dial arc is calibrated to track thespecific
type of movement used.
±15% of meter impedance
-4°F to +149°F (-20°C to +65°C)
High density black plastic
Knife-edge, with black matte finish
Model 2121 & 2121T: 1.25” (31.7mm)
Model 2152: 1.86” (47.2mm)
Model 2122, 2122T, 2142: 2.07” (52.7mm)
Model 2153: 2.48” (63.0mm)
Model 2123, 2123T, 2143: 2.75” (69.8mm)
Model 2154: 3.68” (93.5mm)
Model 2124, 2124T, 2144: 4.09” (103.9mm)
Model 2121 & 2121T: 2oz (0.06kg)
Model 2152: 5oz (0.14kg)
Model 2153: 6oz (0.17kg
Model 2122, 2122T, 2142: 7oz (0.20kg)
Model 2123, 2123T, 2143: 8oz (0.23kg)
Model 2154: 9oz (0.26kg)
Model 2124, 2124T, 2144: 11oz (0.31kg)
Century Simpson Meter |