A-1A 系列技術(shù)參數(shù)表 | ||
型號 | 額定動 作溫度 | 實測動 作溫度 | 保持 溫度 | 極限 溫度 | 額定 電流 | 額定 電壓 | 安規(guī)認(rèn)證 | |||||
UL | CUL | VDE | MITI | PSE | CCC | |||||||
A1-1A | 102℃ | 98±2℃ | 76℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
A2-1A | 115℃ | 112±2℃ | 85℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
A3-1A | 125℃ | 122±2℃ | 97℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
A4-1A | 130℃ | 126±2℃ | 102℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
A5-1A | 135℃ | 131±3℃ | 105℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
A7-1A | 138℃ | 135±2℃ | 108℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
A8-1A | 150℃ | 145±2℃ | 120℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● |
A-2A 系列技術(shù)參數(shù)表 | ||
型號 | 額定動 作溫度 | 實測動 作溫度 | 保持 溫度 | 極限 溫度 | 額定 電流 | 額定 電壓 | 安規(guī)認(rèn)證 [●已通過 ○申請中] | |||||||
UL | TUV | CUL | VDE | CSA | MITI | PSE | CCC | |||||||
A1 | 102℃ | 98±2℃ | 76℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ● | ● |
A2 | 115℃ | 112±2℃ | 85℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ● | ● |
A3 | 125℃ | 122±2℃ | 97℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ● | ● |
A4 | 130℃ | 126±2℃ | 102℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ● | ● |
A5 | 135℃ | 131±3℃ | 105℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ||
A7 | 138℃ | 135±2℃ | 108℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ||
A8 | 150℃ | 145±2℃ | 120℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● |
A-3A 系列技術(shù)參數(shù)表 | ||
型號 | 額定動 作溫度 | 實測動 作溫度 | 保持 溫度 | 極限 溫度 | 額定 電流 | 額定 電壓 | 安規(guī)認(rèn)證 | |||||
UL | CUL | VDE | MITI | PSE | CCC | |||||||
A0-3A | 84℃ | 82±2℃ | 40℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | |
A1-3A | 102℃ | 98±2℃ | 63℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
A2-3A | 115℃ | 112±2℃ | 75℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
A3-3A | 125℃ | 122±2℃ | 85℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
A4-3A | 130℃ | 126±2℃ | 90℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
A5-3A | 135℃ | 131±3℃ | 90℃ | 180℃ | 3A | 250V | ○ | ○ | ● | ● | ● | ● |
A7-3A | 138℃ | 135±2℃ | 93℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
A8-3A | 150℃ | 145±2℃ | 105℃ | 180℃ | 3A | 250V | ● | ● | ● |
| ● | ● |
A-5A 系列技術(shù)參數(shù)表 | ||
型號 | 額定動 作溫度 | 實測動 作溫度 | 保持 溫度 | 極限 溫度 | 額定 電流 | 額定 電壓 | 安規(guī)認(rèn)證 | |||||
UL | CUL | VDE | MITI | PSE | CCC | |||||||
A0-5A | 84℃ | 82±2℃ | 40℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | |
A1-5A | 102℃ | 98±2℃ | 63℃ | 180℃ | 5A | 250V | ○ | ○ | ● | ● | ● | ● |
A2-5A | 115℃ | 112±2℃ | 75℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | ● |
A3-5A | 125℃ | 122±2℃ | 85℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | ● |
A4-5A | 130℃ | 126±2℃ | 90℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | ● |
A5-5A | 135℃ | 131±3℃ | 90℃ | 180℃ | 5A | 250V | ○ | ○ | ● | ● | ● | ● |
A7-5A | 138℃ | 135±2℃ | 93℃ | 180℃ | 5A | 250V | ○ | ○ | ● | ● | ● | ● |
A8-5A | 150℃ | 145±2℃ | 105℃ | 180℃ | 5A | 250V | ● | ● | ● |
| ● | ● |
產(chǎn)品放大圖與尺寸 | ||
|
術(shù) 語 解 釋 | ||
, TR> |
額定動作溫度(TF): | 溫度保險絲按標(biāo)準(zhǔn)規(guī)定方法測試,改變其導(dǎo)電狀態(tài)的溫度。按基于IEC691的安全標(biāo)準(zhǔn) 規(guī)定,溫度保險絲必須在上述溫度+0/-10℃范圍內(nèi)動作。(日本電氣用品管理法規(guī)定公差范圍為+/-7℃范圍內(nèi)動作)。 |
實測動作溫度: | 溫度保險絲在硅油池內(nèi)以每分鐘0.5-1℃速率升溫,檢測電流小于100mA條件下所測得的熔斷溫度。它是溫度保險絲的實際動作溫度。 |
保持溫度(TH): | 溫度保險絲在通過額定電流時,能保持168小時而不會改變其導(dǎo)電狀態(tài)的溫度。 |
極限溫度(TM): | 溫度保險絲能承受10分鐘而不曾發(fā)生重新接通現(xiàn)象的溫度。 |
額定電流(Ir): | 溫度保險絲能承載的電流。 |
額定電壓(Ur): | 溫度保險絲工作電壓。 |