Agilent N5230C網(wǎng)絡分析儀
指標:300 kHz 至 6/13.5/20 GHz 和 10 MHz 至 20/40/50 GHz
主要特性與技術指標
300 kHz 至 6/13.5/20 GHz 和 10 MHz 至 20/40/50 GHz
2 端口或 4 端口,具有兩個內(nèi)置信號源
110 dB 系統(tǒng)和 122 dB 接收機動態(tài)范圍,32,001 個測量點,32 通道
< 0.006 dB rms(選件 22x)
測量速度:每點 4 至 9 μs
描述
PNA-L 網(wǎng)絡分析儀的設計可滿足您的通用網(wǎng)絡分析需求,且價格在您的預算之內(nèi)。
300 kHz 至 6 GHz,2 端口
300 kHz 至 13.5 GHz,提供 2 端口和 4 端口型號
10 MHz 至 20 GHz,提供 2 端口和 4 端口型號
10 MHz 至 40 GHz,2 端口
10 MHz 至 50 GHz,2 端口
直觀的操作方式可簡化測量和加快測量速度
PNA-X 提供 10.4 英寸觸摸屏、采用下拉式菜單的簡單界面、硬鍵和功能鍵。
N5230C PNA-L 系列微波網(wǎng)絡分析儀,300 kHz 至 6/13.5/20 GHz 和 10 MHz 至 20/40/50 GHz
N5230是Agilent公司面向研發(fā)和生產(chǎn)推出的一款PNA-L系列網(wǎng)絡分析儀,它以適中的價格提供強大的功能,可以用于無線通信器件、航空航天設備和設備器件的研發(fā)和制造。
應用混頻器測試、諧波測試、互調失真(IMD)測試、射頻脈沖測試、天線測試、毫米波器件測試、噪聲系數(shù)測試、非線性測試等,也能支持無源器件、有源器件、半導體裸片器件、平衡/差分器件測量和多端口器件測試。
頻率選擇:
N5230C 300kHz-6GHz
N5230C 300kHz-13.5GHz
N5230C 10MHz-20GHz
N5230C 10MHz-40GHz
N5230C 10MHz-50GHz
N5230C-010-Time domain
N5230C-020-300 kHz to 6 GHz, 2 port, standard test set
N5230C-025-300 kHz to 6 GHz, 2 port, configurable test set and extended power range
N5230C-080-Frequency offset mode
N5230C-082-Scalar calibrated converter measurements
N5230C-120 - 300 kHz to 13.5 GHz, 2 port, standard test set;
N5230C-125 - 300 kHz to 13.5 GHz, 2 port, configurable test set and extended power range
N5230C-140 - 300 KHz to 13.5 GHz, 4 port, standard test set
N5230C-145 -300 KHz to 13.5 GHz, 4 port, configurable test set and extended power range
N5230C-146 -300 KHz to 13.5 GHz, 4 port, configurable test set, extended power range, and internal second source
N5230C-1A7 -ISO 17025 compliant calibration
N5230C-1CM -Rackmount kit for installation without handles
N5230C-1CP -Rackmount kit for installation with handles
N5230C-220 -10 MHz to 20 GHz, 2 port, standard test set
N5230C-225 -10 MHz to 20 GHz, 2 port, configurable test set and extended power range
N5230C-240 -300 kHz to 20 GHz, 4 port, standard test set
N5230C-245 -300 kHz to 20 GHz, 4 port, configurable test set and extended power range
N5230C-246 -300 KHz to 20 GHz, 4 port, configurable test set, extended power range, and internal second source
N5230C-301 -Application for use with standard CalPods
N5230C-302 -Application for use with temperature-characterized CalPods
N5230C-420 -10 MHz to 40 GHz, 2 port, standard test set
N5230C-425 -10 MHz to 40 GHz, 2 port, configurable test set and extended power range
N5230C-520 -10 MHz to 50 GHz, 2 port, standard test set
N5230C-525 -10 MHz to 50 GHz, 2 port, configuable test set and extended power range
N5230C-550 -Add 4-port measurement application
N5230C-551 -N-port calibrated measurements
N5230C-897 -Built-in performance test software for Agilent inclusive calibration, perpetual license
N5230C-898 -Built-in performance test software for standards compliant calibration, perpetual license
N5230C-A6J -ANSI Z540 compliant calibration
N5230C-UK6 -Commercial Calibration Certificate with test data
Option 010, Time Domain
This option can be added to any other option combination.
An Option 010 analyzer can display the time domain response of a network or test device by calculating the
inverse Fourier transform of the frequency domain response. This calculation allows the Option 010 analyzer
to show the response of a test device as a function of time or distance. In time domain, the magnitude and
location of a discontinuity and the characteristics of individual transmission paths of a network or test
device can be determined. Time domain operation retains all the accuracy of active error correction.
Option 014, Configurable Test Set
This option is included in Options 225, 425, and 525.
An Option 014 analyzer can be configured to measure high-power devices and devices for high dynamic
range.
For a high-power measurement, external amplifiers and high power attenuators or isolators can be added to
complete the test setup. Test port output power up to 1 Watt (+30 dBm) can be applied to the device under
test (DUT).
Additionally, there is an external reference input that allows the external amplifier’s frequency response and
drift to be ratioed out.
For high dynamic range measurements, front panel jumpers are moved to reverse the signal path through
one of the couplers, allowing for a 15 dB improvement in transmitted signal sensitivity in one direction only.
Jumpers are installed on both ports allowing the user to choose a measurement in either the forward or
reverse direction.
Option 080, Frequency Offset Mode
This option can be added to any other option combination.
This upgrade enables the additional firmware necessary to make frequency offset measurements.
Option 1CM, Rack Mount Flange Kit for Instruments without Handles
Option 1CM provides a rack mount kit that contains a pair of flanges, rack mount rails, and the necessary
hardware to mount the analyzer in an equipment rack with 482.6 mm (19 inches) horizontal spacing.
Additional kits may be ordered from Agilent. Refer to “Rack Mount Kits and Handle Kits” on page 6-48 for
the part numbers.
Option 1CP, Rack Mount Flange Kit for Instruments with Handles
Option 1CP provides a rack mount kit that contains a pair of flanges (cut to adapt to handles), rack mount
rails, and the necessary hardware to mount the analyzer in an equipment rack with 482.6 mm (19 inches)
horizontal spacing.
Additional kits may be ordered from Agilent. Refer to “Rack Mount Kits and Handle Kits” on page 6-48 for
the part numbers.
Option 1E1, Source Attenuators (Extended Power Range)
This option is included in Options 225, 425, and 525.
This option adds a 60-dB step attenuator in the signal path of each of the measurement ports. These step
attenuators are used to adjust the power level (in 10 db steps) to the device under test (DUT) without
changing the power in the reference path.
Option F20, 20 GHz Frequency Range
This is a 2-port network analyzer with an upper frequency limit of 20 GHz. This option is included in Options
220 and 225.
Option F40, 40 GHz Frequency Range
This is a 2-port network analyzer with an upper frequency limit of 40 GHz. This option is included in Options
420 and 425.
Option F50, 50 GHz Frequency Range
This is a 2-port network analyzer with an upper frequency limit of 50 GHz. This option is included in Options
520 and 525.