絕緣電阻(EN61557-2) | 線路阻抗(EN61557-3) | ||
測量范圍: | R:0.25MΩ÷199.9MΩ,Un:50V,100V,250V | 測量范圍: | R L-N(L):0.25ΩΩ÷19.9kΩ |
R:0.15MΩ÷999MΩ,Un:500V,1kV | Ipsc | 計算值 | |
U:0V÷1200V | 額定電壓: | 30V÷500V /15Hz÷500Hz | |
額定電壓: | 100V, 250V, 500V, 1kV | 故障回路阻抗 | (EN61557-3) |
測量電流: | *小1mA在R N=U N×1kΩ/V | 測量范圍 | R L-PE:0.25Ω÷19999Ω |
短路電流: | <3mA | I PFC: | 計算值 |
連續(xù)性 | 額定電壓 | 50V÷500V /15Hz÷500Hz | |
低電阻Ω:(EN61557-4) | 電壓和頻率 | ||
測量范圍Ω: | R:0.16Ω÷1999Ω | U:0V÷550V /f:15Hz÷500Hz | |
測試電流: | *小±200mA,在2Ω | 相旋轉(EN61557-7) | |
開路電壓: | 6.5V÷9.0V | 額定電壓 | 100V÷550V /15Hz÷500Hz |
連續(xù)性7mA | 結果 | 1.2.3或者2.1.3 | |
測量范圍Ω: | R:0.0Ω÷1999Ω | RCD(EN61557-6) | |
測試電流: | *大8.5mA | 測量范圍(I Δ N): | 10,30,100,300,500mA,1A |
開路電壓: | 6.5V÷9.0V | 額定電壓 | 50V÷264V /15Hz÷500Hz |
接觸電壓Uc | 通用 | ||
Uc: | 3.4V÷42.7V(88.1)V | 電源電壓: | 9VDC(6×1.5V電池AA) |
用于Uclim:25V(50V) | 保護等級 | IP42 | |
RS: | 0.00Ω÷9.99kΩ,(RS=UC/I ΔN A) | 充電器電壓: | 12V÷15V |
脫扣時間 | 無滯后RCD | 過壓類別: | 600V,Ⅲ類 |
×1:0ms÷300ms(500ms) | 種類(選項) | ||
×2:0ms÷150ms(200ms) | 保護分類 | 雙絕緣 | |
×5:0ms÷40ms(150ms),UC:0.0V÷99.9V | 污染等級 | 2 | |
脫扣電流 | I Δ :0.2× I ΔN÷1.1× I ΔN AC(÷1.5× I ΔN A) | 種類 | 300V,Ⅲ類 |
t Δ:0ms÷300ms,UC:0.0V÷100.0V | 顯示: | 128×64點陣帶背景光 | |
倍數(shù) | ×0.5,×1,×2, ×5 | 尺寸: | 230寬×103高×115厚 |
對地電阻 | (EN61557-5) | 重量帶電池: | 1.32kg不帶電池 |
R: | 2.00Ω÷1999Ω | 工作溫度范圍 | 0-40℃ |
開路電壓: | <45V | TRMS電流I: | 0.0mA÷19.99A |
短路電流 | <20mA | 照明: | E: 0.1勒克斯÷19.99千勒克斯 |