無論在實驗室還是在生產(chǎn)線,微波功率計R&S NRP都是你正確的選擇。新穎的R&S NRP系列功率計的通用性主要歸因于新近開發(fā)的功率探頭。這些探頭是智能的獨立儀器,他們與基本單元通訊,或經(jīng)由數(shù)字接口與一個pc機通信?,F(xiàn)在實現(xiàn)的智能傳感技術(shù),建立了根據(jù)通用性和準確性要求的新標準。
如果說功率探頭的動態(tài)范圍決定了它的普及程度是真的話,NRP-Z11 和 NRP-Z21將有機會贏的。這是次使寬帶調(diào)制信號的動態(tài)范圍達到了90Db,同時由于噪聲和零偏移決定的下限功率測量能保持在-67dBm的很低的水平。這種性能不會改變,甚至在測量單個gsm時隙信號時。對于單個突發(fā)脈沖的平均功率的信號-觸發(fā)測量或功率-時間特性模板的生成,新型傳感器還可以提供比所有現(xiàn)用常規(guī)設(shè)計的探頭還有寬的動態(tài)范圍。
R&S®NRP-Z
Power Sensors
For operation with R&S®NRP2 base unit or via USB on a Laptop/PC
Three-Path Diode Power Sensors
R&S®NRP-Z11 Order No. 1138.3004.02 / 1138.3004.04
Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 8 GHz,
N connectorR&S®NRP-Z21 Order No. 1137.6000.02
Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 18 GHz,
N connectorR&S®NRP-Z22 Order No. 1137.7506.02
Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -57 dBm to +33 dBm,
Frequency range: 10 MHz to 18 GHz,
N connectorR&S®NRP-Z23 Order No. 1137.8002.02
Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -47 dBm to +42 dBm,
Frequency range: 10 MHz to 18 GHz,
N connectorR&S®NRP-Z24 Order No. 1137.8502.02
Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -42 dBm to +45 dBm,
Frequency range: 10 MHz to 18 GHz,
N connectorR&S®NRP-Z31 Order No. 1169.2400.02 / 1169.2400.04
Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 33 GHz,
3.5 mm connector
Two-Path Diode Power Sensors
R&S®NRP-Z211 Order No. 1417.0409.02
Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 8 GHz,
N connectorR&S®NRP-Z221 Order No. 1417.0309.02
Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
Thermal Power Sensors
R&S®NRP-Z51 Order No. 1138.0005.02
Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -30 dBm to +20 dBm,
Frequency range: DC to 18 GHz,
N connectorR&S®NRP-Z52 Order No. 1138.0505.02
Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 33 GHz,
3.5 mm connectorR&S®NRP-Z55 Order No. 1138.2008.03
Thermal Power Sensor model .03
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 40 GHz,
2.92 mm connectorR&S®NRP-Z55 Order No. 1138.2008.04
Thermal Power Sensor model .04
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 44 GHz,
2.92 mm connectorR&S®NRP-Z56 Order No. 1171.8201.02
Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 50 GHz,
2.4 mm connectorR&S®NRP-Z57 Order No. 1171.8401.02
Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 67 GHz,
1.85 mm connectorR&S®NRP-Z58 Order No. 1173.7031.02
Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 110 GHz,
1.00 mm connector
Wideband Power Sensors
R&S®NRP-Z81 Order No. 1137.9009.02
Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 18 GHz,
N connectorR&S®NRP-Z85 Order No. 1411.7501.02
Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.92 mm connectorR&S®NRP-Z86 Order No. 1417.0109.40
Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.4 mm connector
Average Power Sensors
R&S®NRP-Z91 Order No. 1168.8004.02 / 1168.8004.04
Average Power Sensor
Accurate average power measurements for EMC applications
Measurement range: -67 dBm to +23 dBm,
Frequency range: 9 kHz to 6 GHz,
N connectorR&S®NRP-Z92 Order No. 1171.7005.02 / 1171.7005.42
Average Power Sensor
Accurate average power measurements for EMC applications
Measurement range: -57 dBm to +33 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
Level Control Sensors
R&S®NRP-Z28 Order No. 1170.8008.02
Level Control Sensor
Highly accurate signal level generation in conjunction with a signal generator
Measurement range: -67 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connectorR&S®NRP-Z98 Order No. 1170.8508.02
Level Control Sensor
Highly accurate signal level generation in conjunction with a signal generator
Measurement range: -67 dBm to +20 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
Power Sensors for other R&S instruments
R&S®NRP-Z27 Order No. 1169.4102.02
Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 18 GHz,
N connectorR&S®NRP-Z37 Order No. 1169.3206.02
Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 26.5 GHz,
3.5 mm connector
Accessories
R&S®NRPZ-K1 Order No. 1418.9800.03
R&S®NRPV license for one R&S®NRP-Zxx power sensor
Convenient power measurements via PC application
R&S®NRP-Z2 Order No. 1146.6750.03 / 1146.6750.05 / 1146.6750.10 / 1146.6750.15
Sensor Extension Cable
In some cases the signal source is far away from the base unit. Therefore four different sensor extension cables are available, to get a total length of 3, 5 or 10 meters.
R&S®NRP-Z3 Order No. 1146.7005.02
USB Adapter (active)
R&S®NRP-Z3 active USB adapter has been developed for applications requiring external triggering of the power sensor. It also offers a separate power supply.
R&S®NRP-Z4 Order No. 1146.8001.02 / 1146.8001.04 / 1146.8001.06 / 1146.8001.11
USB Adapter (passive)
For all R&S®NRP-Z sensors. The R&S®NRP-Z4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lenghths: 2.0m, 0.5m, 0.15m and 1m (for panel-mount)
R&S®NRP-Z5 Order No. 1146.7740.02
USB Sensor Hub
R&S®NRP-Z5 can host up to 4 R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected