QDR-365 紫外線燈、黑光燈、紫外線探傷燈
QDR-365 紫外線黑光燈是美國Spectronics公司推出的手持式led紫外線探傷燈。QDR-365 紫外線黑光燈主要用于熒光滲透探傷、熒光磁粉探傷行業(yè),采用了冷光源的紫外線led。QDR-365系列紫外線黑光燈有4個型號,分別是QDR-365,QDR-365BL,QDR-365S,QDR-365SBL。
QUADRAN™ 365 Series
Versatile, Dual-Intensity, Multi-LED, Broad-Beam NDT Inspection Lamps!QUADRAN™ 365 Series NDT lamps feature four ultra-hi-flux UV-A LEDs plus a convenient white light LED to quickly switch between fluorescent inspection and flaw location. A unique dual-intensity feature provides both high and standard UV-A and white light output for added versatility.If you are interested in QDR-365 Inspection Lamps, please contact Shanghai Feng Chi Instrument Co., telephone 021 -.The lamps’ broad-beam configuration produces an extremely wide coverage area, making them ideal for both handheld and in-line applications. Models are available either with or without integral black light filters to meet your specific inspection requirements。
Features
Dual-intensity capability: High setting produces a nominal steady-state UV-A intensity as high as 8,000 μW/cm2; standard setting produces a nominal steady-state intensity of 4,500 μW/cm2, both at 15 inches (38 cm)
Extremely large coverage area of up to 6 inches (15 cm), with a minimum UV-A intensity of 2,000 μW/cm2
Low visible light emission — less than 2 foot-candles (22 lux)
Conveniently located rocker switches for quick and easy control of light sources
Built-in fan keeps LEDs cool to maintain optimum light output during extended use
Rubber bumper with Borofloat® glass lens protects LEDs from damage
Rugged, modular construction allows for easy field serviceability
QDR-365 Inspection Lamps
Lamp handle pin receptacle allows for easy attachment of various Spectroline® mounting accessories for in-line inspection applications (accessories sold separately)
Choice of standard 8 foot (2.4 m) or extra-long 20 foot (6.1 m) heavy-duty power cord with AC plug and rubber boot. Also available: Optional industrial power supply or in-line power supply with cord sets (sold separately). All power supplies available in 120V, 230V, 240V and 100V models.UV-absorbing spectacles and soft carrying case included
When the QDR-365 is in high intensity mode, the lamp provides a nominal steady-state UV-A intensity of 8,000 μW/cm2 at 15 inches (38 cm).When switched to the standard intensity mode, the QDR-365 provides a nominal steady-state UV-A intensity of 4,500 μW/cm2 at 15 inches (38 cm).In addition, the lamp has a high/low switch to control the white light LED output.
As the wavelength of the QUADRAN™ 365 moves into the visible light range, the black light filters significantly reduce the output of the lamp at 400 nm.
Typical wavelength output profile of QUADRAN™ 365 Series lamps with and without black light filter.
Also Available:
QUADRAN™ 365M Series portable, battery-operated AC/DC lamp kits. Include QUADRAN™ 365 UV lamp, rechargeable NiMH battery pack, AC and DC cord sets, smart AC charger, UV-absorbing spectacles and soft carrying case.
UV Switch Setting | Nominal steady-state UV-A (365 nm) intensity at 15 inches (38 cm) ➀ | Visible light measurement | UV-A coverage area (at minimum 2000 μW/cm2) |
QDR-365 | |||
Standard | 4,500 μW/cm2 maximum | < 2 foot-candles (22 lux) | 5 in (13 cm) |
High | 8,000 μW/cm2 | < 2 foot-candles (22 lux) | 6 in (15 cm) |
QDR-365BL | |||
Standard | 4,500μW/cm2 maximum | < 2 foot-candles (22 lux) | 4 in (10 cm) |
High | 7,000μW/cm2 | < 2 foot-candles (22 lux) | 6 in (15 cm) |
Light Source: 4 UV-A LEDs, 1 White Light LED
Lamp Style: Pistol Grip
Lamp Head (WxH): 6 x 5.5 in (15 x 14 cm)
Length: 10 in (25 cm
Weight: 3 lb (1.36 kg)
White Light LED Intensity:
High setting: 300 foot-candles (3,229 lux)
Low setting: 10 foot-candles (108 lux)
Power Requirement
AC lamp
(QDR-365, QDR-365BL) 120VAC* power cord supplied with lamp
AC/DC lamp
(QDR-365M, QDR-365MBL) 120VAC*/12VDC
Battery Pack:
Type
12V, NiMH (rechargeable)
Run time
High intensity: 2.5 hours (continuous)
Standard intensity: 4.5 hours (continuous)
Charge time
2 hours
* Also available in 120V, 230V, 240V and 100V versions
➀ All UV-A intensity readings were taken with Spectroline® AccuMAX™ Series meter, and are factory set to the values shown