HI-2200射頻電磁場(chǎng)強(qiáng)儀 | |||||||||||||||||||
|
| ||||||||||||||||||
射頻電磁輻射分析儀HI-2200是一套操作簡(jiǎn)單、使用方便的電磁測(cè)量系統(tǒng)。它小巧輕便,可手持,并不易受測(cè)量場(chǎng)所的影響, 例如在塔頂?shù)任恢谩?/SPAN>HI-2200顯示實(shí)時(shí)和空間的平均值。它的特點(diǎn)還包括數(shù)據(jù)記錄容量大,使用者可以選擇讀數(shù)單位,調(diào)整報(bào)警范圍和RS-232數(shù)據(jù)界面。 | |||||||||||||||||||
HI-2200配有射頻電場(chǎng)探頭E100, 頻率范圍從100 kHz到5 GHz,大動(dòng)態(tài)測(cè)量范圍0.3~800 V/m??蛇x擇的磁場(chǎng)探頭覆蓋頻率范圍300 kHz~30 MHz 或5 MHz~300 MHz。所有的探頭可直接與HI-2200的讀出模塊連接,輕松使用。 | |||||||||||||||||||
HI-2200以其良好的靈敏度,大動(dòng)態(tài)的測(cè)量范圍,方便實(shí)用的設(shè)計(jì)理念*適合于下列領(lǐng)域的應(yīng)用普及。 | |||||||||||||||||||
應(yīng)用領(lǐng)域: | |||||||||||||||||||
環(huán)境電磁輻射監(jiān)測(cè) 移動(dòng)通訊、廣播電視等單位的電磁輻射監(jiān)測(cè) | |||||||||||||||||||
工作場(chǎng)所的電磁場(chǎng)安全監(jiān)測(cè) 無(wú)線電管理部門 | |||||||||||||||||||
國(guó)防電子設(shè)備的電磁安全檢測(cè) 航空航天設(shè)備電磁環(huán)境監(jiān)測(cè) | |||||||||||||||||||
機(jī)場(chǎng)雷達(dá)電磁環(huán)境的安全監(jiān)測(cè) EMC等電磁兼容測(cè)試領(lǐng)域 | |||||||||||||||||||
相關(guān)院所及高校的EMF研究 | |||||||||||||||||||
產(chǎn)品特點(diǎn): | |||||||||||||||||||
操作簡(jiǎn)單 測(cè)試精度高 輕便 | |||||||||||||||||||
65000個(gè)數(shù)據(jù)記錄 空間平均功能 動(dòng)態(tài)范圍廣 | |||||||||||||||||||
Electrical Specifications For Additional Probes探頭規(guī)格 | |||||||||||||||||||
型號(hào) | 傳 感 器 類 型 | 頻 率 范 圍 | 動(dòng) 態(tài) 范 圍 | ||||||||||||||||
E100 | 電場(chǎng)E-Field isotropic | 100 kHz – 5 GHz | 0.3 -800 V/m (Single Range) | ||||||||||||||||
H200 | 磁場(chǎng)H-Field isotropic | 5 MHz - 300 MHz | 30 mA/m - 10 A/m (Single Range) | ||||||||||||||||
H210 | H-Field isotropic | 300 kHz -30 MHz | 0.3 - 30 A/m (Single Range) | ||||||||||||||||
C300 | E-Field % of FCC std | 100 kHz – 8 GHz | < 1% - 999% of FCC std | ||||||||||||||||
C310 | E-Field % of ICNIRP std | 100 kHz – 8 GHz | < 1% - 999% of ICNIRP | ||||||||||||||||
機(jī)械規(guī)格 | |||||||||||||||||||
型號(hào) | 操作溫度 | 主機(jī)尺寸 | 探頭高 | 重量 | |||||||||||||||
HI-2200 | -10℃ to 50℃ | 85mm×160mm×30mm | 260mm | 0.6kg | |||||||||||||||
可選擇顯示單位 | |||||||||||||||||||
電場(chǎng)測(cè)量選擇單位:V/m,μW/cm2,mW/cm2,W/m2 | |||||||||||||||||||
磁場(chǎng)測(cè)量選擇單位:A/m,mA/m,μW/cm2,mW/cm2,W/m2 | |||||||||||||||||||
HI-2200 RF Survey Meter | |||||||||||||||||||
A simple solution for basic RF safety measurements, the HI-2200 RF Survey Meter provides a compact measurement system including interchangeable probes. | |||||||||||||||||||
Key Features | |||||||||||||||||||
Broadband Frequency Range | |||||||||||||||||||
Economical Solution to Broadcast/Telecom Safety Monitoring Needs & Environmental Monitoring | |||||||||||||||||||
Fitted Carry Case | |||||||||||||||||||
Hand-strap & Safety Lanyard Mount | |||||||||||||||||||
Interchangeable Probe Heads | |||||||||||||||||||
One Hand Operation | |||||||||||||||||||
Optional Fiber Optic Link | |||||||||||||||||||
Small/Lightweight for minimal field perturbance | |||||||||||||||||||
Description | |||||||||||||||||||
The HI-2200 RF Survey Meter is a lightweight probe, easy to hold instrument for less accessible measurement locations such as towers and ladder access situations. The display module has easy to use Spatial and Temporal Averaging on a large LCD display. Additional features include Data Logging capability, User Selectable Readout Units, and Adjustable Alarm Threshold, and an RS-232 Data Interface. | |||||||||||||||||||
Communications: With greater dependence on all forms of electronic communication, the need to monitor personnel exposure is an ongoing concern. The compact size and simple operating controls of the HI-2200 RF Survey probe offer the perfect solution for all telecommunications service providers. Broadcast, Commercial Radio, TV: High power radio and TV transmission facilities are required by government regulators in most countries to limit RF exposure to both the general public and employees. Simple yet accurate field measurement instrumentation is necessary for a safe environment. | |||||||||||||||||||
Health Care Facilities: Concerns regarding medical personnel exposure and potential electromagnetic interference are more easily addressed with the HI-2200 RF Survey Meter. Safety and biomedical personnel can now have easy access to measurement tools for monitoring RF exposure and equipment interference issues. Industrial: A safe workplace for employees is an important responsibility for all companies. EMF employee exposure safety guidelines now exist in most countries. IEEE, ICNIRP, and national standards provide guidelines for worker RF exposure. The HI-2200 RF Survey Meter is a cost effective means of monitoring workplace safety. | |||||||||||||||||||
Standard Configuration | |||||||||||||||||||
Calibration | |||||||||||||||||||
Model HI-2200 Metering Unit | |||||||||||||||||||
1/4 X 20 Tripod Mount | |||||||||||||||||||
Handgrip Strap | |||||||||||||||||||
Shoulder Harness | |||||||||||||||||||
RS-232 Data Interface Cable (9-pin D-sub connector) | |||||||||||||||||||
Data Upload Software | |||||||||||||||||||
User Manual | |||||||||||||||||||
Fitted Carry Case | |||||||||||||||||||
One Year Warranty | |||||||||||||||||||
Options | |||||||||||||||||||
Additional Probes | |||||||||||||||||||
Optical Cable (up to 100 meters) | |||||||||||||||||||
Optical Remote Data Link | |||||||||||||||||||
Probe View II PC Software | |||||||||||||||||||
Electrical Specifications For Additional Probes | |||||||||||||||||||
Model Dynamic Range Frequency Range Sensor Detection Type | |||||||||||||||||||
C300 <1% - 999% of FCC std 100 kHz- 8 GHz E-Field % of FCC std | |||||||||||||||||||
C310 <1% - 999% of ICNIRP 100 kHz- 8 GHz E-Field % of ICNIRP std | |||||||||||||||||||
E100 0.3 - 800 V/m 100 kHz- 5 GHz E-Field isotropic | |||||||||||||||||||
H200 30mA/m- 10 A/m 5 MHz- 300 MHz H-Field isotropic | |||||||||||||||||||
H210 0.3-30 A/m 300 kHz - 30 MHz H-Field isotropic | |||||||||||||||||||
Electrical Specifications | |||||||||||||||||||
Frequency Minimum:100 kHz | |||||||||||||||||||
Frequency Maximum:5 GHz | |||||||||||||||||||
Averaging Modes: Linear, RMS, Spatial | |||||||||||||||||||
Frequency Response:1 Mz - 4 GHz, +/- 1 dB | |||||||||||||||||||
Internal Memory:> 65,000 data points | |||||||||||||||||||
Isotropicity:+/- 0.1 dB | |||||||||||||||||||
Level Range:0.3 - 800 V/m | |||||||||||||||||||
Operating Time:> 20 hrs; 4-AA Batteries | |||||||||||||||||||
Overload:> 1200 V/m | |||||||||||||||||||
Resolution:0.01 V/m | |||||||||||||||||||
Sensitivity:0.3 V/m | |||||||||||||||||||
User Selectable Units:V/m, A/m, T, mW/cm2 |