一、產(chǎn)品簡(jiǎn)介:
環(huán)保水泥細(xì)度負(fù)壓篩析是 水泥細(xì)度檢測(cè)儀器,采用電機(jī)驅(qū)動(dòng)負(fù)壓,具結(jié)構(gòu)簡(jiǎn)單,操作方便,降低能耗等優(yōu)點(diǎn)。
Product introduction:
Environmental protection cement fineness negative pressure sieve analysis is the finest cement fineness detection instrument. It adopts electric motor to drive negative pressure. It has the advantages of simple structure, convenient operation and reduced energy consumption.
二、技術(shù)參數(shù):
★篩析測(cè)試細(xì)度:80um(可選配45um負(fù)壓篩)
★篩析自控時(shí)間:2min
★工作負(fù)壓可調(diào):4000-6000pa
★工作電壓:220V2
★噴氣嘴轉(zhuǎn)速:30±2rpm
★電源:AC220V
★整機(jī)功率:900w
★外形尺寸:500x300x780mm
★凈重:30kg
Technical parameters:
★ Screening test fineness: 80um (optional 45um negative pressure screen)
★ Screening automatic control time: 2min
★ Adjustable working negative pressure: 4000-6000pa
★ Working voltage: 220V2
★ Air nozzle speed: 30 ± 2rpm
★ Power supply: AC220V
★ Overall power: 900w
★ Dimensions: 500x300x780mm
★ Net weight: 30kg
三、試驗(yàn)步驟:
★篩析試驗(yàn)前,調(diào)節(jié)數(shù)顯式時(shí)間繼電器,使其設(shè)定在120s,再把負(fù)壓篩放在篩座上,蓋上篩蓋,打開(kāi)電源,調(diào)節(jié)負(fù)壓至-4000~-6000pa范圍內(nèi),然后關(guān)機(jī)。
★稱(chēng)取試樣25g,置于潔凈的負(fù)壓篩中,蓋上篩蓋,再次啟動(dòng)儀器,連續(xù)篩析,在此期間如有試樣附著在篩蓋上,可輕敲篩蓋使試樣落下,當(dāng)篩析滿(mǎn)120s后,儀器自動(dòng)停止。
★篩畢,用天平秤重篩余物。
水泥負(fù)壓篩析儀試驗(yàn)結(jié)果計(jì)算
水泥試樣篩余百分?jǐn)?shù)按下式計(jì)算:
F=
式中:F-水泥試樣篩余百分?jǐn)?shù)(%)
ms—水泥篩余物的質(zhì)量(g)
m—水泥試樣的質(zhì)量(g)
計(jì)算結(jié)果精確到0.1%
Three, test steps:
★ Before the sieve analysis test, adjust the digital display time relay to 120s, then place the negative pressure screen on the screen base, cover the screen cover, turn on the power, and adjust the negative pressure to the range of -4000 ~ -6000pa , And then shut down.
★ Weigh 25g of the sample, place it in a clean negative pressure sieve, cover the sieve cover, start the instrument again, and continue sieving. During this period, if the sample is attached to the sieve cover, tap the sieve cover to make the sample Falling down, when the sieve analysis is completed for 120s, the instrument automatically stops.
★ After screening, use a balance to weigh the residue.
Calculation of Test Results of Cement Negative Pressure Sieve Analyzer
The remaining percentage of the cement sample sieve is calculated as follows:
F =
In the formula: F- Percentage of cement sample sieve (%)
Ms—the quality of cement sieve residue (g)
M—the quality of the cement sample (g)
The calculation result is accurate to 0.1%
四、注意事項(xiàng):
1、定期倒掉集塵瓶中的水泥。
2、如果使用一段時(shí)間后負(fù)壓達(dá)不到 標(biāo)要求(-4000~-6000pa)時(shí),請(qǐng)清潔吸塵器中的收塵袋。
3、吸塵器連續(xù)工作不應(yīng)超過(guò)15分鐘,否則易過(guò)熱燒壞。
4、水泥細(xì)度負(fù)壓篩析儀試驗(yàn)篩的清洗試驗(yàn)篩必須經(jīng)常保持潔凈,篩孔通暢。如其篩孔被水泥堵塞影響篩余量時(shí),可用弱酸浸泡,用毛刷輕輕地刷洗,用淡水沖凈、晾干。
5、篩余結(jié)果的修正為使試驗(yàn)結(jié)果可比,應(yīng)采用試驗(yàn)篩修正數(shù)方法修正7.1條的計(jì)算結(jié)果。修正系數(shù)的測(cè)定,按附錄B(補(bǔ)充件)進(jìn)行。
6、負(fù)壓篩法與水篩法或手工干篩法測(cè)定的結(jié)果發(fā)生爭(zhēng)議時(shí),以負(fù)壓篩法為準(zhǔn)。附錄A手工干篩試驗(yàn)操作方法(補(bǔ)充件) A1稱(chēng)取水泥試樣50g倒入符合GB3350.7要求的干篩內(nèi)。 A2用一只手執(zhí)篩往復(fù)搖動(dòng),另一只手輕輕拍打,拍打速度每分鐘約120次,每40次向同一方向轉(zhuǎn)動(dòng)60°,使試樣均勻分布在篩網(wǎng)上,直至每分鐘通過(guò)的試樣量不超過(guò)0.05g為止。 A3稱(chēng)量篩余物,按7.1條計(jì)算試驗(yàn)結(jié)果。
Six, matters needing attention:
1. Discard the cement in the dust collection bottle regularly.
2. If the negative pressure does not reach the required standard (-4000 ~ -6000pa) after using for a period of time, please clean the dust bag in the vacuum cleaner.
3. The vacuum cleaner should not work continuously for more than 15 minutes, otherwise it will be easily overheated and burned.
4. Cleaning of the cement fineness negative pressure sieve analyzer test sieve The test sieve must always be kept clean and the sieve holes are unobstructed. If the sieve holes are blocked by cement and affect the sieve balance, they can be soaked in weak acid, gently brushed with a brush, rinsed with fresh water, and dried.
5. Revision of sieve residue results In order to make the test results comparable, the calculation results of Article 7.1 shall be corrected by the test sieve correction method. The determination of the correction coefficient is carried out in accordance with Appendix B (Supplementary Document).
6. In case of dispute between the results of negative pressure sieve method and water sieve method or manual dry sieve method, the negative pressure sieve method shall prevail. Appendix A. Manual dry sieve test operation method (supplement) A1 Weigh 50g of cement sample and pour it into a dry sieve that meets the requirements of GB3350.7. A2 shakes the sieve with one hand, and pats it gently with the other hand. The tapping speed is about 120 times per minute, and it is rotated 60 ° in the same direction every 40 times, so that the sample is evenly distributed on the screen until the test passes every minute The sample amount does not exceed 0.05g. A3 Weigh the sieve residue and calculate the test result according to Article 7.1.