硫化氫檢測管4HT Hydrogen sulphide
Hydrogen sulphide No.4HT
H2S
Performance |
Measuring Range | 1 to 2 % | 2 to 20 % | 20 to 40 % |
Number of Pump Strokes | 2 | 1 | 1/2 |
Correction Factor | 1/2 | 1 | 2 |
Sampling Time | 1 minute per pump stroke | ||
Detecting Limit | 0.2% (n=2) | ||
Color Change | Pale Blue → Blackish Brown | ||
Reaction Principle | H2S + CuSO4 → CuS + H2SO4 | ||
Coefficient of Variation | 10% (for 2 to 6 %), 5% (for 6 to 20 %) | ||
Shelf Life | 3 Years | ||
Corrections for temperature & humidity | Unnecessary | ||
Store the tubes at cool and dark place. |
Possible coexisting substances and their interferences | (NOTE) |
Substance | Concentration | Interference | Change color by itself |
Sulfur dioxide | 5% | Minus error | No discoloration |
Mercaptans | 10% | Plus error | No discoloration |
Other substance measurable with this detector tube |
Calibration gas generation | High pressure gas cylinder method |
TLV-TWA | TLV-STEL | Explosive range |
10ppm | 15ppm | 4.0 to 44% |