DY220 Weight Indicator
Specifications:
配料精準,操作簡易方便,多三路繼電器輸出,DY220稱重顯示控制器,采用高速、高精度A/D轉(zhuǎn)換和單片機控制技術(shù),對電阻應(yīng)變式稱重傳感器信號進行智能處理,自動跟蹤系統(tǒng)零點,實時顯示物料重量,并輸出定值控制信號。本產(chǎn)品操作簡單,維護方便,能根據(jù)用戶需要靈活配置,可適用于多種電子稱重配料.
1. Analog input
Analog inputs use 20 bits AD chip, Count Speed up to 80 times / sec, the measurement accuracy of 0.2%
Display range -9999 ~ 19999
The largest sub-degree 50000
For the bridge voltage 5V, 100mA
2. The switch output
3 relay or OC outputs. Relay contacts AC 250V / 1A, OC output drive 100mA / 48V optional.
3. Transmission output
Output 4-20mA, 0-10V, 12bit precision driving 500 ohm load. Optional features.
4. communication port
485,232 communication interface, upload executable modbusRTU and active protocol. This function is optional. Only can choose one function with transmission function
5. A simple comparison output
Features: 3 output meter can be set to be greater than or less than the comparative comparison. When the measured value exceeds the upper limit output is active when the measured value is less than the upper limit minus hysteresis output is invalid. If the output is less than comparison, the measured value is less than the lower limit of the output is active when the measured value is greater than the lower limit plus hysteresis invalid.
Menu Structure
3.1 parameter modification. Standby mode, press [k1] + password to enter the password written 100. Entering advanced parameters (13 parameters later) password is written 105.
Specific steps are as follows: Press [k1] key, there will be 00000, after press [k4] key to move the blinking digit moves to the flashing digit to be modified, press [k3] to modify the blinking digits, password changes is correct, press [k1] key to enter the set parameters, and then press [k1] to switch the set of parameters, select the parameter to be modified, press [k4] enter the parameters after the modification is completed, press [k1] OK to return to the measurement interface [k2]
3.2 weight calibration. Standby mode, press [k2], to see details of the third page (V: calibration method)
3.3 Key cleared. Standby mode, press [k4], and the measured value is less than zero range is completed is cleared.
3.4 restore the factory settings. 3.1 according to enter parameter modification (but need to enter a password to use special password) to switch to the first 42 parameters, enter a number between 11-19, and then press the [k1] to switch to the next parameter, press [k2 [to exit the way to restore the instrument parameters 1-9 initial state.
Display symbolically
A 1 Alarm output value
b 2 alarm output value
c 3 alarm output value
d alarm hysteresis
AL alarm status
st running state
E A / D code value
dA transmitter output code
U Software version
Calibration method
Standby mode, press [k2], appears E0xxxx, press [k4] is cleared, there E00000 zero calibration is complete. Press [k2] qualifying C00000, plus a known standard weights or heavy objects, press [k4], and then by pressing [[k3] to increase the value + [k4] to move the blinking digit, modified weight by weight, stable, press [k2] OK, the calibration is complete, the value and weight of the weights should be consistent, if not the exact same order again once calibrated, accurate after calibration, press [k1] return force measurement interface.