Ⅱ、主要技術指標:
表1 DL08-21系列電阻箱主要技術指標一覽表
示值 Ω 型號 | × 100M | × 10M | × 1M | × 100k | × 10k | × 1k | × 100 | × 10 | × 1 | × 0.1 | × 0.01 |
DL08-21 | — | — | — | — | 0.1 | 0.1 | 0.5 | 1 | 2 | 5 | — |
DL08-21a | — | — | — | — | 0.1 | 0.1 | 0.1 | 0.5 | 1 | 2 | — |
DL08-21b | — | — | — | — | 0.1 | 0.1 | 0.1 | 0.5 | 1 | 2 | — |
DL08-21c | — | — | — | — | — | 0.1 | 0.1 | 0.5 | 1 | 2 | 5 |
DL08-21d | — | — | — | 0.5 | 0.1 | 0.1 | 0.5 | 1 | 2 | — | — |
DL08-21e | — | — | 1 | 0.5 | 0.1 | 0.1 | 0.5 | 1 | — | — | — |
DL08-21f | — | 2 | 1 | 0.5 | 0.1 | 0.1 | 0.5 |
|
|
|
|
DL08-21g | 5 | 2 | 1 | 0.5 | 0.1 | 0.1 |
|
|
|
|
|
電流≤(A) | 60 μ | 180 μ | 0.6 m | 1.8 m | 6 m | 18 m | 60 m | 180 m | 0.6 | 1.5 | 3 |
1、調節(jié)范圍:
DL08-21:(0~9)×(0.1~10k)Ω =0~99.9999 kΩ
DL08-21a:(0~10)×(0.1~10k)Ω=0~111.1110 kΩ
DL08-21b:(0~9)×(0.1~10k)Ω=0~99.9999 kΩ
DL08-21c:(0~10)×(0.01~1k)Ω=0~11.11110 kΩ
DL08-21d:(0~10)×(1~100k)Ω=0~1.111110MΩ
DL08-21e:(0~10)×(10~1M)Ω =0~11.11110MΩ
DL08-21f:(0~10)×(100~10M)Ω =0~111.1110MΩ
DL08-21g:(0~10)×(1k~100M)Ω=0~1.111110GΩ
2、零值電阻:30±5mΩ
3、電阻箱的基本誤差如下表1規(guī)定:
4、每檔電阻容許通過電流見表1:
5、電阻箱電路與外殼之間的絕緣強度,經得住頻率為50赫茲,2000伏交流電的作用,歷時1分鐘。
6、電阻箱電路與外殼之間的絕緣電阻不少于1000兆歐。
7、電阻箱重量約1.3公斤;尺度為200×150×110mm
Ⅲ、使用注意事項:
1、 正確使用電阻箱時應先旋轉一下各組旋鈕,使內阻接觸穩(wěn)定可靠。
2、 電阻箱在使用中絕不應超過規(guī)定的大允許電流值。
3、 當只需小電阻值變化時,則將線接到“0”和另一小示值接線柱,可以減小電阻箱內的引線電阻。
4、 電阻箱應放在有遮蔽的房間內,空氣溫度從+10℃~40℃相對濕度在80%以下不應含有能引起腐蝕的有害雜質。
Ⅳ、附則:
1、隨產品一起供應的文件包括有:
⑴裝箱單
⑵產品使用說明書
⑶產品合格證明書
2、本電阻箱按照ZBY162—83國家專業(yè)標準制造。
3、電阻箱的保證期限自出廠日期起十二個月。
加工定制 | 是 | 類型 | 直流電阻箱 | ||
測量范圍 | 0~99999.9(Ω) | 準確度等級 | 0.1% | ||
外形尺寸 | 200×150×110(mm) | 適用范圍 | 學校、工廠、科研單位等 | 重量 | 1.5KG |
來源 | 自己生產 |