国产精品成人网站,日韩视频二区,亚洲成人手机电影,怡红院国产

服務(wù)咨詢(xún)

產(chǎn)品求購(gòu)企業(yè)資訊會(huì)展供應(yīng)

發(fā)布詢(xún)價(jià)單
儀表網(wǎng)>產(chǎn)品庫(kù)>儀表下游>電力新能源>輸配電>Hawke防爆連接器Hawke MKIV Controlex Ex c...
  • Hawke防爆連接器Hawke MKIV Controlex Ex connector
  • Hawke防爆連接器Hawke MKIV Controlex Ex connector

Hawke防爆連接器Hawke MKIV Controlex Ex connector

參考價(jià)
面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 型號(hào)
  • 品牌
  • 所在地上海
  • 更新時(shí)間2022-12-04
  • 廠商性質(zhì)生產(chǎn)廠家
  • 入駐年限5
  • 實(shí)名認(rèn)證已認(rèn)證
  • 產(chǎn)品數(shù)量1384
  • 人氣值184789
客服在線(xiàn) 索取相關(guān)資料 在線(xiàn)詢(xún)價(jià)

聯(lián)系方式:張凱文 查看聯(lián)系方式

聯(lián)系我們時(shí)請(qǐng)說(shuō)明是 儀表網(wǎng) 上看到的信息,謝謝!

同類(lèi)產(chǎn)品

上海頤品自動(dòng)化科技有限公司(EPIN AUTOMATION)是一家集生產(chǎn),銷(xiāo)售,進(jìn)出口加工為一體的企業(yè)。公司主要生產(chǎn)加工黃銅鍍鎳電纜接頭和尼龍電纜接頭以及附件,金屬軟管和管接頭,尼龍波紋管和管接頭,PVC走線(xiàn)槽,ABS和PC電氣接線(xiàn)盒,電氣控制柜,尼龍?jiān)鷰В?hào)碼管,接線(xiàn)端子,絕緣套管和熱縮套管以及橡膠密封件等電工電氣配線(xiàn)器材。另外,還代理和分銷(xiāo)歐洲進(jìn)口的電氣品牌產(chǎn)品,部分產(chǎn)品通過(guò)RoHS,CE,UL,CSA,TUV,VDE,ATEX,ABS等認(rèn)證。

公司擁有一支積極進(jìn)取,技術(shù)精良的設(shè)計(jì)和銷(xiāo)售團(tuán)隊(duì),并與國(guó)內(nèi)外多家機(jī)電生產(chǎn)廠商建立了長(zhǎng)期友好的合作關(guān)系,銷(xiāo)售國(guó)內(nèi)外品牌電纜保護(hù)產(chǎn)品和其他機(jī)電產(chǎn)品。為其產(chǎn)品在中國(guó)區(qū)的市場(chǎng)推廣、技術(shù)咨詢(xún)、產(chǎn)品銷(xiāo)售、售后跟蹤等提供專(zhuān)業(yè)周到的服務(wù),為客戶(hù)節(jié)約了大量的生產(chǎn)時(shí)間和制造成本。

客戶(hù)至上,誠(chéng)信為本,為客戶(hù)創(chuàng)造價(jià)值是我司的經(jīng)營(yíng)宗旨,我們將以快速的產(chǎn)品供應(yīng),完善的售后服務(wù),竭誠(chéng)為工業(yè)自動(dòng)化、機(jī)械制造,電子通信、電力電氣、鐵路機(jī)車(chē),儀器儀表,航空船舶,港口設(shè)備,石油石化等領(lǐng)域的客戶(hù)提供高質(zhì)量的產(chǎn)品和服務(wù)。另外,公司也承接工業(yè)自動(dòng)控制和電氣工程項(xiàng)目設(shè)計(jì)和集成,歡迎新老客戶(hù)咨詢(xún)洽談。

目前,我公司代理和經(jīng)銷(xiāo)的主要電氣品牌有以下產(chǎn)品:
1、電纜接頭系列:
Hawke,CMP, CCG,Peppers,Cembre,Pflitsch,Wiska等;
2、尼龍軟管系列:
REIKU,FlexiconInterflex,PMA,Adaptaflex,Kopex等;
3、金屬軟管系列:Teaflex,Adaptaflex,T&B,Armed,Anaconda,Legrand等;
4、PVC線(xiàn)槽系列:EPIN, SES,KSS,Panduit,KAKU,Unex,Pflitsch等;
5、電氣接線(xiàn)盒等:Rittal,Hibox,F(xiàn)ibox,Boxco,E-tan,HAWA等;
6、扎帶號(hào)碼管等:KSS,AVC, SES,Panduit,Richco等;
7、電子元器件等:ATMEL,BOURNS,Spansion,Techwell,Broadcom等。

Looking for a quotation on a large volume order? We would be happy to help by providing a quick response, inventory status, and special pricing, when available. Please call us or send e-mail to us and a representative will be in touch with you within one business day to answer any questions and quote your request. We offer quality service and products, on time delivery, and lowest prices. Our store has been designed to provide you with simple and fast on-line purchasing.

If you have any questions or comments about our products, please contact us freely. Thank you for shopping with us! We hope you will come back again and again. We are always looking to improve our website, so please feel free to give us your comments, suggestions, or questions. Thanks for helping us serve you better!

點(diǎn)擊展示更多內(nèi)容
Hawke防爆連接器Hawke MKIV Controlex Ex connector
Hawke防爆連接器Hawke MKIV Controlex Ex connector
上海頤品自動(dòng)化,:
Hawke防爆連接器Hawke MKIV Controlex Ex connector 產(chǎn)品詳情

Hawke防爆連接器Hawke MKIV Controlex Ex connector
Hawke防爆連接器Hawke MKIV Controlex Ex connector
上海頤品自動(dòng)化,:

Hawke MKIV Controlex Ex connector

Hazardous Area Connector

Tamb: -40°C to +60°C. ex logo II2 GD Exdb IIC Gb, Extb IIIC Db T95 IP66, 67 & DTS01 deluge protected.

Overview

The 4th generation of Controlex logo connectors include many features and refinements as a result of consumer feedback, which makes them particularly suitable for control and low/medium power applications. The robust stainless steel body can hold up to 60 contacts and will accept conductor sizes ranging between 0.5mm² and 35mm², operating up to 125A and 750V.

Hawke MKIV Controlex logo Features

1、Easy Fieldwireable

Pin and socket inserts are numbered front and back to assist wiring and avoid termination errors. Crimp and solder inserts available.

2、Internal Keyway Spacer

Eases accessibility for termination as tube fitted after termination complete, along with allowing easy installation into the required keyed position (See 4)

3、Locking Pin

Optional locking pin provides the facility for mated connectors to be permanently locked, via the use of a padlock, ensuring they cannot be separated under load. (Padlock not supplied)

4、Keying Position

The unique visual 5 position insert keying system (3 on Ex16) along with the integral machined keyways prevent contact damage and ensures safe use by eliminating the possibility of misconnection of adjacent circuits.

5、Running Coupler

Allows the connector to be installed onto a pre-assembled cable gland. Connector is rear loading and includes locking engaging nut.

6、Acme Thread at Mating Interface

Unique ACME thread offers a smooth and quick fully mating action.

7、Fully Inspectable Flameproof Barrier

Provides direct inspection of the flameproof seal and offers users the peace of mind that the connector is safe for installation.

8、Anti-Rotation Device

Connector plugs and receptacles come complete with anti-rotation ring, which when fitted between the connector and gland, helps to eliminate the possibility of the gland loosening, locking this in position.

MKIV Controlex logo Connector Dimensions

ControlEx Connector Dimensions

The flameproof cap must be fitted to the connector before the power is restored to the disconnected circuit. The receptacle cap and plug cap are available in acetal and provide an IP rating of IP66/67. They may only be used when the socket or plug is not re-energised following disconnection. For connector plugs and connector receptacles cable glands are required to terminate incoming cables. Hawke recommend the ICG 653/UNIV cable gland is used.

HAWKE Ex SERIES DIMENSIONS (MM)
DimensionEx16Ex25Ex32Ex40Ex50Ex63
A127152152152152148
B105128129129129126
ØC364653606683
ØD374957657690
E128152152152152152
ØF324551597083
G151515151515
H (nominal)202020202020
J (Aperture clearance hole)5565758595115
* Thread L (1.5mm Pitch)M25M32M40M50M63M75
M545456565656
N A/F364655658095
R151515161617
S383838393940
ØT283442516073
U404040404040
Thread V (1.5mm Pitch)M20M25M32M40M50M63
X (nominal)547070707067
ØY66768391102117
4959667485100
ØZ8799105117129147
?708288100112130
* Bulkhead entry thread L can be adapted to other sizes. This may affect the overall length of unit.
Contact us for details.

MKIV Controlex logo Inserts

ControlEx Connector Inserts

Cup Sizes and Selection Table

CUP DIAMETERS
Insert
Size
Internal Diameter of cup (mm)
Nominal
SolderedCrimped
1.5mm²22
2.5mm²33
6mm²3.53.2
10mm²74
16mm²75
25mm²86.5
35mm²88.3
INSERT SELECTION TABLE
Shell Size 16Shell Size 25Shell Size 32Shell Size 40Shell Size 50Shell Size 63
3 x 1.5mm² + Earth4 x 1.5mm² + Earth12 x 1.5mm² + Earth24 x 1.5mm² + Earth37 x 1.5mm² + Earth49 x 1.5mm² + Earth
4 x 1.5mm² + Earth9 x 1.5mm² + Earth19 x 1.5mm² + Earth30 x 1.5mm² + Earth27 x 2.5mm² + Earth60 x 1.5mm² + Earth
-12 x 1.5mm² + Earth10 x 2.5mm² + Earth19 x 2.5mm² + Earth13 x 6mm² + Earth37 x 2.5mm² + Earth
-4 x 2.5mm² + Earth12 x 2.5mm² + Earth4 x 25mm² + Earth--
-7 x 2.5mm² + Earth4 x 6mm² + Earth4 x 35mm² + Earth--
-4 x 6mm² + Earth6 x 6mm² + Earth---
--3 x 10mm² + Earth---
--4 x 10mm² + Earth---
--3 x 16mm² + Earth---
--4 x 16mm² + Earth---
Note: Inserts for use in bulkhead receptacles are solder termination only, for contact sizes of 6mm² and above.
Hawke Controlex logo connectors have a maximum working voltage of 660V DC (660V AC) as standard.
3rd & 4th generation Controlex logo connectors can be connected together within certification.
Other voltages available on special request.

MKIV Controlex logo Calculations

To select the shell size of the connector, it is essential that you calculate the dissipated wattage of the arrangement. This ensures that the arrangement does not exceed the maximum permitted temperature classification with regard to the upper ambient temperature for the area of installation. (please refer to table 1 below for the maximum allowable dissipated wattage per connector size).

TABLE 1
Connector SizeUpper Ambient
Temperature of +40°C
Upper Ambient
Temperature of +50°C
Upper Ambient
Temperature of +60°C
Temperature ClassTemperature ClassTemperature Class
T6T5T6T5T6T5
Ex165W7W4W6W2.6W4.6W
Ex258W11W6W10W4W7W
Ex3210.5W14.5W8W12W5.4W9W
Ex4012W17W9W14W5.5W10.5W
Ex5013W20W10W17W6.5W12.5W
Ex6317W29W13W24W8.5W17W
 Maximum allowable dissipated wattage
Other ambient temperature options can be extrapolated from
table 1 above, or contact Hawke International for more information.
TABLE 2
Contact SizeCombined Cable And Contact Resistance (Ohms)Contact
Current
Rating
SolderedCrimped
1.5mm²0.0166Ω0.0173Ω10 amps
2.5mm²0.0102Ω0.0109Ω17 amps
6mm²0.0047Ω0.0054Ω30 amps
10mm²0.0027Ω0.0033Ω78 amps
16mm²0.0018Ω0.0024Ω78 amps
25mm²0.0012Ω0.0018Ω125 amps
35mm²0.0009Ω0.0015Ω125 amps

Dissipated Wattage Calculation

Equation definitions:

W = Dissipated wattage factor of the connector

N = The number of conductors to be terminated/number of contacts required. (Note: A contact comprises of a pin and socket).

I = The current requirement per contact. (Note: This must be equal to or less than the maximum current rating of the contact, as shown in table 2 above).

R = The combined cable and contact resistance (see table 2 above).

Values pertinent to these definitions must then be input into the relevant fields below to calculate the dissipated wattage (W) of your chosen arrangement:

1. W = N x I ² x R
NIRDissipated Wattage
(Watts)
W
    
 

(Note: The results must be lower than the maximum figure shown in table 1 above, for the appropriate temperature class and ambient temperature).

e.g. T6 40°C ambient application with 9 x 1.5mm² conductors running at 7 amps.
N = 9 contacts
I = 7 amps
R = 0.0166 Ω (1.5mm² soldered combined cable and contact resistance)

Therefore W = 9 x 49 x 0.0166 = 7.32 watts.
Therefore an Ex25 Connector should be specified for this application as the shell size can accommodate the required 9 x 1.5mm² pin / socket inserts (see insert selection table) and the resultant dissipated wattage (7.32 watts) is below the maximum permitted 8 watts (see table 1 above).

This equation can also be transposed to facilitate the calculation of the maximum number of conductors permitted in your selected connector (calculator 2 below ) and the maximum allowable current within the upper ambient temperature of your location (calculator 3 below).

2. number of conductors formula
WRIMaximum Number Of
Conductors
N
    
 
3. maximum current formula
WNRCurrent
(Amps)
I
    
 
Note: The result must not exceed the maximum current rating of the contacts (see table 2 above)

Note: Unless otherwise requested, connectors will be marked as T5 with an upper ambient temperature of +40°C.

Order Codes

Hawke International does not recommend the use of their ControlEx Connectors in applications where rigid PVC/SWA/PVC power cabling (typically to BS 6346 standards or equivalnts) is used in portable/semi-portable applications.

When ordering, select the relevant code from each block as shown in the example below:
Controlex logo/Exd-32-S-CP-V-19 x 1.5-S-C-FL-FPC-P-R25-A-1-T

Controlex logoSelect CodeDescriptionExample Code
ProtectionExdFlameproofExd
Shell Size161632
2525
3232
4040
5050
6363
MaterialSStainless SteelS
Connector StyleCPConnector PlugCP
CRConnector Receptacle
BRBulkhead Receptacle
Keying SystemVVariable Keyway (All)V
FFixed Keyway
(only available if purchasing terminated)
Number Of Contacts See insert selection19
XNo Insert
Contact Size See insert selection1.5
Insert TypePPinS
SSocket
XNo Insert
Termination Style
* Note: Inserts for use in Bulkhead receptacles are solder termination only for contact sizes of 6mm² and above.
SSolder*C
CCrimp*
XNo Insert
Flange Type ♦
Note: CP or CR only - one per mating pair.
FLMounting FlangeFL
SFSplit Flange
(can be retro fitted after termination)
Cap TypeFRCFlameproof Receptacle CapFPC
FPCFlameproof Plug Cap
PRCPlastic Receptacle Cap
PPCPlastic Plug Cap
Locking Pin ♦PLocking Pin
(only one required per mating pair)
P
Alternative Cable Gland Entry ♦R20Reduced Cable Gland Entry M20
(Ex25 only)
R25
R25Reduced Cable Gland Entry M25
(Ex40 & Ex32 only)
R32Reduced Cable Gland Entry M32
(Ex50 & Ex40 only)
R40Reduced Cable Gland Entry M40
(Ex63 & Ex50 only)
R50Reduced Cable Gland Entry M50
(Ex63 only)
CertificationAATEX/IECEx/EAC/InmetroA
NATEX/IECEx/EAC/Inmetro/NEC 505
Voltage reduced to 600V
Ambient Rating and Temperature Class
T5 +40°C will be supplied as standard if alternative not specified.
1T5 +40°C Standard1
2T5 +50°C
3T5 +60°C
4T6 +40°C
5T6 +50°C
6T6 +60°C
Termination ♦TTermination RequiredT

♦ If not required omit selection character from order code.

Find A Connector Modifier

Ordering Information

For ordering information and codes, please see order codes tab.

MKIV Controlex logo Calculations

To select the shell size of the connector, it is essential that you calculate the dissipated wattage of the arrangement. This ensures that the arrangement does not exceed the maximum permitted temperature classification with regard to the upper ambient temperature for the area of installation. (please refer to table 1 below for the maximum allowable dissipated wattage per connector size).

TABLE 1
Connector SizeUpper Ambient
Temperature of +40°C
Upper Ambient
Temperature of +50°C
Upper Ambient
Temperature of +60°C
Temperature ClassTemperature ClassTemperature Class
T6T5T6T5T6T5
Ex165W7W4W6W2.6W4.6W
Ex258W11W6W10W4W7W
Ex3210.5W14.5W8W12W5.4W9W
Ex4012W17W9W14W5.5W10.5W
Ex5013W20W10W17W6.5W12.5W
Ex6317W29W13W24W8.5W17W
 Maximum allowable dissipated wattage
Other ambient temperature options can be extrapolated from
table 1 above, or contact Hawke International for more information.
TABLE 2
Contact SizeCombined Cable And Contact Resistance (Ohms)Contact
Current
Rating
SolderedCrimped
1.5mm²0.0166Ω0.0173Ω10 amps
2.5mm²0.0102Ω0.0109Ω17 amps
6mm²0.0047Ω0.0054Ω30 amps
10mm²0.0027Ω0.0033Ω78 amps
16mm²0.0018Ω0.0024Ω78 amps
25mm²0.0012Ω0.0018Ω125 amps
35mm²0.0009Ω0.0015Ω125 amps

Dissipated Wattage Calculation

Equation definitions:

W = Dissipated wattage factor of the connector

N = The number of conductors to be terminated/number of contacts required. (Note: A contact comprises of a pin and socket).

I = The current requirement per contact. (Note: This must be equal to or less than the maximum current rating of the contact, as shown in table 2 above).

R = The combined cable and contact resistance (see table 2 above).

Values pertinent to these definitions must then be input into the relevant fields below to calculate the dissipated wattage (W) of your chosen arrangement:

1. W = N x I ² x R
NIRDissipated Wattage
(Watts)
W
    
 

(Note: The results must be lower than the maximum figure shown in table 1 above, for the appropriate temperature class and ambient temperature).

e.g. T6 40°C ambient application with 9 x 1.5mm² conductors running at 7 amps.
N = 9 contacts
I = 7 amps
R = 0.0166 Ω (1.5mm² soldered combined cable and contact resistance)

Therefore W = 9 x 49 x 0.0166 = 7.32 watts.
Therefore an Ex25 Connector should be specified for this application as the shell size can accommodate the required 9 x 1.5mm² pin / socket inserts (see insert selection table) and the resultant dissipated wattage (7.32 watts) is below the maximum permitted 8 watts (see table 1 above).

This equation can also be transposed to facilitate the calculation of the maximum number of conductors permitted in your selected connector (calculator 2 below ) and the maximum allowable current within the upper ambient temperature of your location (calculator 3 below).

2. number of conductors formula
WRIMaximum Number Of
Conductors
N
    
 
3. maximum current formula
WNRCurrent
(Amps)
I
    
 
Note: The result must not exceed the maximum current rating of the contacts (see table 2 above)

Note: Unless otherwise requested, connectors will be marked as T5 with an upper ambient temperature of +40°C.

Order Codes

Hawke International does not recommend the use of their ControlEx Connectors in applications where rigid PVC/SWA/PVC power cabling (typically to BS 6346 standards or equivalnts) is used in portable/semi-portable applications.

When ordering, select the relevant code from each block as shown in the example below:
Controlex logo/Exd-32-S-CP-V-19 x 1.5-S-C-FL-FPC-P-R25-A-1-T

Controlex logoSelect CodeDescriptionExample Code
ProtectionExdFlameproofExd
Shell Size161632
2525
3232
4040
5050
6363
MaterialSStainless SteelS
Connector StyleCPConnector PlugCP
CRConnector Receptacle
BRBulkhead Receptacle
Keying SystemVVariable Keyway (All)V
FFixed Keyway
(only available if purchasing terminated)
Number Of Contacts See insert selection19
XNo Insert
Contact Size See insert selection1.5
Insert TypePPinS
SSocket
XNo Insert
Termination Style
* Note: Inserts for use in Bulkhead receptacles are solder termination only for contact sizes of 6mm² and above.
SSolder*C
CCrimp*
XNo Insert
Flange Type ♦
Note: CP or CR only - one per mating pair.
FLMounting FlangeFL
SFSplit Flange
(can be retro fitted after termination)
Cap TypeFRCFlameproof Receptacle CapFPC
FPCFlameproof Plug Cap
PRCPlastic Receptacle Cap
PPCPlastic Plug Cap
Locking Pin ♦PLocking Pin
(only one required per mating pair)
P
Alternative Cable Gland Entry ♦R20Reduced Cable Gland Entry M20
(Ex25 only)
R25
R25Reduced Cable Gland Entry M25
(Ex40 & Ex32 only)
R32Reduced Cable Gland Entry M32
(Ex50 & Ex40 only)
R40Reduced Cable Gland Entry M40
(Ex63 & Ex50 only)
R50Reduced Cable Gland Entry M50
(Ex63 only)
CertificationAATEX/IECEx/EAC/InmetroA
NATEX/IECEx/EAC/Inmetro/NEC 505
Voltage reduced to 600V
Ambient Rating and Temperature Class
T5 +40°C will be supplied as standard if alternative not specified.
1T5 +40°C Standard1
2T5 +50°C
3T5 +60°C
4T6 +40°C
5T6 +50°C
6T6 +60°C
Termination ♦TTermination RequiredT

♦ If not required omit selection character from order code.

 

 

中國(guó)區(qū)分銷(xiāo)商:
上海頤品自動(dòng)化科技有限公司
Shanghai Epin Automation Co.,Ltd.

Website:www.epinautomation。。com
:sales@epinautomation.com
*:

 

關(guān)鍵詞:連接器
熱門(mén)產(chǎn)品
產(chǎn)品名稱(chēng)參考價(jià)地區(qū)公司名稱(chēng)更新時(shí)間 
ESVG6000靜止無(wú)功發(fā)生器-輸配電 面議 北京易艾斯德科技有限公司 2020-12-14 在線(xiàn)詢(xún)價(jià)
WA170智能除濕裝置-輸配電 面議 大導(dǎo)電氣(上海)有限公司 2020-12-12 在線(xiàn)詢(xún)價(jià)
ISOM K-40h / D-15h-輸配電 面議 溯高美索克曼電氣(上海)有限公司 2020-12-12 在線(xiàn)詢(xún)價(jià)
ISOM Digiware L-60h-輸配電 面議 溯高美索克曼電氣(上海)有限公司 2020-12-12 在線(xiàn)詢(xún)價(jià)
ISOM Digiware D-55h-輸配電 面議 溯高美索克曼電氣(上海)有限公司 2020-12-12 在線(xiàn)詢(xún)價(jià)
16MM帶邊纏繞管 16MM-輸配電 面議 上海富繼電氣有限公司 2020-11-23 在線(xiàn)詢(xún)價(jià)
免責(zé)申明

所展示的信息由會(huì)員自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會(huì)員負(fù)責(zé),儀表網(wǎng)對(duì)此不承擔(dān)任何責(zé)任。儀表網(wǎng)不涉及用戶(hù)間因交易而產(chǎn)生的法律關(guān)系及法律糾紛,糾紛由您自行協(xié)商解決

友情提醒 :本網(wǎng)站僅作為用戶(hù)尋找交易對(duì)象,就貨物和服務(wù)的交易進(jìn)行協(xié)商,以及獲取各類(lèi)與貿(mào)易相關(guān)的服務(wù)信息的平臺(tái)。為避免產(chǎn)生購(gòu)買(mǎi)風(fēng)險(xiǎn),建議您在購(gòu)買(mǎi)相關(guān)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。過(guò)低的價(jià)格、夸張的描述、私人銀行賬戶(hù)等都有可能是虛假信息,請(qǐng)采購(gòu)商謹(jǐn)慎對(duì)待,謹(jǐn)防欺詐,對(duì)于任何付款行為請(qǐng)您慎重抉擇!如您遇到欺詐等不誠(chéng)信行為,請(qǐng)您立即與儀表網(wǎng)聯(lián)系,如查證屬實(shí),儀表網(wǎng)會(huì)對(duì)該企業(yè)商鋪?zhàn)鲎N(xiāo)處理,但儀表網(wǎng)不對(duì)您因此造成的損失承擔(dān)責(zé)任!

關(guān)于我們|網(wǎng)站導(dǎo)航|本站服務(wù)|會(huì)員服務(wù)|網(wǎng)站建設(shè)|特色服務(wù)|旗下網(wǎng)站|友情鏈接|在線(xiàn)投訴|興旺通|供應(yīng)信息

儀表網(wǎng)-儀器儀表行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺(tái)

Copyright ybzhan.cn All Rights Reserved法律顧問(wèn):浙江天冊(cè)律師事務(wù)所 賈熙明律師ICP備案號(hào):浙B2-20100369-24

客服熱線(xiàn):0571-87756399,87759942加盟熱線(xiàn):0571-87756399展會(huì)合作:0571-87759945客服郵箱:873582202@qq.com 投稿郵箱:ybzhan@qq.com

網(wǎng)站客服:服務(wù)咨詢(xún):對(duì)外合作:儀表采購(gòu)群: 儀表技術(shù)群:

版權(quán)所有©浙江興旺寶明通網(wǎng)絡(luò)有限公司


提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個(gè)人信息: