YXA-150 (YAXC-150) 氨用電接點壓力表采用彈簧管作為測壓敏感元件,主要用于氨氣壓
力的測量。 并通過儀表指針的觸點與設(shè)定指針的觸點相接通 (斷開) 控制系統(tǒng)中電路的開關(guān),
以達(dá)到自動控制和發(fā)報警信號的目的。
本儀表可與各類膜片隔離器相連接,制成隔膜電接點壓力表,用于測量腐蝕性強、粘度大、
易結(jié)晶介質(zhì)的壓力。
YXA-150 (YAXC-150) ammonia electric contact pressure gauge ,adopted bourdon as
sensitive element ,especially in the measurement of ammonia pressure. The pointer of
instrument will make contacts turn on or cut with set finger contacts, leading to the cut and
turn-on of control system for the purpose of automatic control and
alarm.
This model can be matched with many kinds of capsule insulators ,crank out diaphragm
electric contact pressure gauge,measuring the pressure of corrosion ,glutinous and crystal-
lographic medium.
主要技術(shù)參數(shù)
執(zhí)行標(biāo)準(zhǔn):JB/T9272-1999
測量范圍:zui?。?-0.1MPa
zui大:0-60MPa
負(fù)壓zui小: -0.1~0MPa
負(fù)壓zui大: -0.1~2.4MPa
指示精度:± 1.5%
設(shè)定精度:± 4%
接點數(shù)量:1 或 2 個
測壓部件材質(zhì):接頭 45# 鋼;測壓元件 不銹鋼
外殼材質(zhì):碳鋼
儀表玻璃:有機玻璃
防護(hù)等級:IP54
zui高工作電壓:380V.AC或 220V.DC
zui大電流:普通1A
觸頭功率:普通 30VA
環(huán)境溫度:-40-+70℃
溫度影響:使用溫度偏離+ 25℃時,其設(shè)定點誤差變
化不大于 0.6%/10℃
Main technic index
Execntive standard: JB/T9272-1999
Range: minimum 0-0.1MPa
maximum 0-60MPa
minimum minus voltage -0.1~0MPa
maximum minus voltage -0.1~2.4MPa
Indicating accuracy: ±1.5%
Set accuracy: ± 4%
Quantity of contacts: 1 or 2
Materials of measurement parts: Socket 45# steel;
meaterials of element: stainless steel
Matenal of case: Carbon steel
Windows: orgamic glasses
Protection class: IP54
Maximum working voltage: 380V.AC or 220V.DC
Maximum current: 1A
Contacts power: 30VA
Ambient temperature: -40-+70℃
Effect of temperature: when the temperature deuiates
from + 25℃, the error of setpoint is less than 0.6%/10℃